![background image](http://html.mh-extra.com/html/daikin/atc25qrv16/atc25qrv16_service-manual_501360018.webp)
Fan Motor / Fan Rotor
Si041402EC
16
Removal Procedure
9. Fan Motor / Fan Rotor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
2
Remove the 2 screws
of the right side plate.
Release the fan motor
lead wire from the 3
hooks and remove the
right side plate.
When reassembling the fan
motor and the fan rotor,
provide as much as 5 mm
(0.2 inch) of play between
the side face of the rotor and
the bottom frame.
3
4
Remove the 2 screws
of the fan motor fixing
plate.
Remove the fan motor
fixing plate.
5
Loosen the screw and
remove the fan motor
and the fan rotor.
(1) Insert the fan motor allowing
for approx. 5 mm (0.2 inch)
of play.
(2) Tighten the fan rotor screw
until it stops. Then give the
screw one more turn.
(3) If the fan rotor rotates
appropriately, tighten the
screw completely.
(4) If not, repeat the procedure
from (1).
Right side plate
Hook
Hook
(R20095)
5 mm (0.2 inch)
Side face of rotor
(R18879)
Side face of
bottom frame
Fan motor
fixing plate
(R20096)
(R9582)
Fan motor
(R20097)
Fan rotor
(R20098)