![background image](http://html.mh-extra.com/html/daikin/atc25qrv16/atc25qrv16_service-manual_501360012.webp)
PCBs
Si041402EC
10
Removal Procedure
2
3
Unfasten the 3 hooks.
Slide the electrical box
cover to the left and
remove it.
3. Remove the signal
receiver unit.
When reassembling the
signal receiver unit, make
sure the 2 lower hooks are
also securely fastened.
1
Unfasten the upper
hook and remove the
signal receiver unit.
Step
Procedure
Points
Hook
Electrical
box cover
(R23419)
Hook
Hook
Signal receiver
unit
(R20076)