Page 2: ...place where air is circulated throughout the room The air blows slightly slant to the right When you want to remove house dust setting up the air purifier in low rooms is effective When you want to re...

Page 3: ...mum 2m from lighting TVs radios stereos and aerials This unit can disturb TV pictures and generate interference Illumination can weaken remote controller signal reception sensitivity and discolor the...

Page 4: ...to the room Note cannot be washed with water 12 Filter container Six replacement pleated filters are included 13 Ventilation fan 14 Air inlet 15 Remote controller storage slot Stores the accessory rem...

Page 5: ...operation 5 Airflow rate indicator green page 7 Lit by the set airflow rate setting The air volume lamp is on during automatic or manual operation 6 Turbo mode indicator green page 7 Lit during turbo...

Page 6: ...ly 1 year but if the reception becomes difficult replace the batteries with new coin type battery CR2025 Coin type battery close to the recommended usage period may need to be replaced soon In order t...

Page 7: ...of the bio antibody filter on the hooks 2 locations of the plasma ionizer 3 Restore the pre filter Hook the bottom part of the pre filter on the bottom hooks 2 locations of the plasma ionizer and the...

Page 8: ...e will be lit in the OFF timer setting indicator When the set time is reached the operation will automatically stop The set time can be changed if the button is pressed while the timer is operating 8...

Page 9: ...lfunction may occur Cleaning the air inlet for the dust odor sensor Clean dusts clogged in the air inlet for the dust odor sensor Use crevice nozzle of a cleaner for cleaning Cleaning the front panel...

Page 10: ...exposed to the sun Do not clean with water hotter than 50 C Do not burn with fire Color changes or deformation may occur and the unit may become unusable Replacing the bio antibody filter The bio anti...

Page 11: ...et switch with a sharp material such as a tooth pick to turn off the replacement sign It will beep NOTE Replace a pleated filter Contact your dealer for replacement pleated filter It is not necessary...

Page 12: ...t to cut your hands with the opposing pole plate or ionizer wires It is safer to use rubber gloves CAUTION There are ionizer wires at back of the opposing pole plate When attaching or removing be care...

Page 13: ...equipment may result Rinse with running water Soak in water or warm water to remove detergent about 30 minutes Caution Soak well as cleaning sign may be on even after cleaning if any detergent remain...

Page 14: ...with a soft cloth 2 Streamer discharger Clean off the internal resin part with a soft cloth For removal see page 11 3 Ionizing frame Clean off the resin part with a soft cloth Use a cotton bud to wip...

Page 15: ...le plate while opening the knobs one at a side of the plasma ionizer 3 Insert securely until it clicks 4 Attach another side of the opposing pole plate 2 Attach the streamer discharger 1 Insert bottom...

Page 16: ...ER button The receive sound will beep and the setting lamp will flash 4 Unplug the power plug one time and then after 3 seconds or more plug it in again This completes the settings NOTE If the operati...

Page 17: ...eign matter For other cases contact your dealer Air does not come out Cleaning effect is not obtained Is the unit installed at a location where the flow does not pass or are there obstructions close t...