8 Technical data

Installation manual

27

EBLQ+EDLQ011~W1
Daikin Altherma low temperature monobloc
4P522031-1 – 2018.01

Electrical connection diagram

3 cor

e

4 or 3 cor

e

4D115044-1

1

1

X3M: 1-2

X3M: 5-6

X3M: 3-4

X5M: 3-4

X5M: 1-2

X5M: 5-6

X5Y

X2M: 5-6

X2M: 12-11

X2M: 13-14-15

X2M: 9-10

X8M: 5-4-3

X1M: L-N-PE

A4P: X5A: 1-2-3

X2M: 13-15

X8M: 3-4

X8M: 1-2

X2M: 7-8

X2M: 9-10

X2M: 1a-2a

X1M: L-N-PE

A4P: X5A: 1-2-3

F1B: L1-L2-L3

X15M: 1-2

X15M: 3-4

X15M: 5-6-7

230V

2x0.75

X8M: 6-7

X8M: 6-7-10

X8M: 8-9

X2M: 20-21

X2M: 22-23

X8M: 10

X2M: 1-2-1a

X2M: 1-2-1a

X8M: 4-5

X2M: 1-2

X8M: 6-7

2

2

2

2

X11M: 3-4-5-6

A7P: X1M: H-C-com

X2M: L-N

A3P: X1M: 1-3

230 V

2x0.75

2x0.75

230 V

230 V

A3P: X1M: C-com-H

230 V

230 V

230 V

230V

3

3

230 V

230 V

K1

X2M: 3-4

Standard part

Monobloc unit

Power supply

unit preferential kWh rate power supply:

230 V + earth

unit power supply: 230 V + earth

2 core

2 core

3 core

3 core

Optional part

Field supply

Optional part

Option box

X4M: L-N-earth

Preferential kWh rate power supply contact

1 core

communication

communication

2 core

2 core

2 core

2 core

230V

230V

230V

Control box

External room thermostat / Heat pump convector

(main and/or additional zone)

X4M: 1-2 + earth

signal

signal

signal

2 or 3 core

2 core

2 core

Only for normal power supply installation

Only for preferential kWh rate power supply installation

normal kWh rate power supply for unit: 230 V

or L-N + earth

Backup heater power supply (3/6/9 kW): 400 V or 230 V + earth

Booster heater power supply (3 kW): 230 V + earth

Main: X2M: 1-2

Add: X2M: 1a-2

Only for

(heat pump convector)

Only for *KRTR

(wireless room thermostat)

Only for *KRTW

(wired room thermostat)

2 core

(3m included)
signal

R2T

External sensor

(floor or ambient)

Only for *KRTETS

External indoor thermistor

Electricity pulse

meter input 2

Electricity pulse

meter input 1

Space cooling/heating

On/OFF output

Ext. heat source (eg boiler)

Alarm Output

Only for KRCS01-1

3 core

communication

3 core

Power supply

Optional part

Domestic hot 

water tank

Only for *DLQ*

Standard: 4 low voltage wires

Optional: 4 high voltage wires

Inside: 6 or 7 wires to BUH

Only for *BLQ*

Standard: 4 low voltage wires

Optional: 5 high voltage wires

Inside: 6 or 7 wires to BUH

Valve kit: 3 wires

Standard: 4 low voltage wires

Optional: 4 high voltage wires

2 low voltage wires 

Standard part

Optional part

A5P: P1-P2 user interface

A5P: P1-P2 user interface

Only for *KRUCB*

communication

2 core

communication

2 core

signal

signal

3 core

4 core

4 core for H only operation

5 core for C/H operation

2 core for H only operation

3 core for C/H operation

Valve kit

BUH option

BUH

BUH

Valve kit

Control

Box

Control

Box

Control

Box

External outdoor thermistor

Only for EKRSCA1

Optional part

signal

2 core

2 core

2 core

2 core

2 core

signal

signal

2 core

signal

3 way valve

M3S (when *KHW is installed)

selection domestic hot water-floor heating

Control box power supply: 230 V + earth

3 core

Dual setpoint application

(refer to installation manual)

signal

2 core

Typical configuration

Notes:

- In case of signal cable: keep minimum distance 

  to power cables > 5 cm

- Available heaters: see combination table

Optional

part

DHW pump

Shut-off valve

Field supply

2 core

2 core 230V

X6M

Only for *KHWP*/*HYC*

Only for *KHWS*V3

3 core 3Gx2.5

3 core 3Gx2.5

X4M: 1-2-earth

X4M: 1-2-earth

Booster heater

R5T - thermistor

water temperature

Booster heater

signal

Summary of Contents for Altherma EBLQ014CAV3

Page 1: ...ow temperature monobloc English Installation manual Daikin Altherma low temperature monobloc EBLQ011CAV3 EBLQ014CAV3 EBLQ016CAV3 EBLQ011CAW1 EBLQ014CAW1 EBLQ016CAW1 EDLQ011CAV3 EDLQ014CAV3 EDLQ016CAV3...

Page 2: ...B C 500 250 100 A B C E 500 250 150 1000 500 500 D 500 500 D E 1000 500 B D 250 500 B D E 250 250 400 400 400 400 400 1000 150 150 150 150 150 150 150 1000 1000 1000 500 HD HU HD HU HB HU HD HU HB HU...

Page 3: ...sti za p edpokladu e jsou vyu v ny v souladu s na imi pokyny odpov daj n sleduj c m norm m nebo normativn m dokument m u skladu sa slijede im standardom ima ili drugim normativnim dokumentom ima uz uv...

Page 4: ...py the system settings from the first to the second user interface 14 5 1 4 To copy the language set from the first to the second user interface 15 5 1 5 Quick wizard Set the system layout after first...

Page 5: ...5 C in domestic hot water operation mode 3 2 Preparing water piping NOTICE In case of plastic pipes make sure they are fully oxygen diffusion tight according to DIN 4726 The diffusion of oxygen into t...

Page 6: ...m flow rate can be checked by way of the pump test check that the user interface does NOT display error 7H NOTICE When circulation in each or certain space heating loops is controlled by remotely cont...

Page 7: ...nd washers field supply as follows 150 6 2 0 350 3 4 5 3 5 5 a mm 2 6 1 5 6 M12 a Make sure not to cover the drain holes INFORMATION The recommended height of the upper protruding part of the bolts is...

Page 8: ...n places where strong wind can tilt the unit take following measure 1 Prepare 2 cables as indicated in the following illustration field supply 2 Place the 2 cables over the outdoor unit 3 Insert a rub...

Page 9: ...ng Prevent from freezing 5 C 10 15 10 C 15 25 15 C 20 35 20 C 25 25 C 30 NOTICE The required concentration might differ depending on the type of glycol ALWAYS compare the requirements from the table a...

Page 10: ...ter field supply indicates a pressure of 2 0 bar 5 Purge as much air as possible from the water circuit For instructions see 6 Commissioning on page 21 6 Refill the circuit until the pressure is 2 0 b...

Page 11: ...emove reposition the switch box and gain access to other components during service CAUTION Do NOT push or place redundant cable length in the unit 4 4 2 To connect the main power supply 1 Connect the...

Page 12: ...4C From the top a b PCB b 1 4D From the top centre a PCB b b 1 a Notch this part for the wiring to pass through with nippers etc b Secure the wiring to the front part of the casing using the wiring re...

Page 13: ...er NOT all settings are accessible via both methods If so the corresponding table columns in this chapter are set to N A not applicable Method Column in tables Accessing settings via the breadcrumb in...

Page 14: ...other settings 6 Push to confirm the modification of the parameter 7 At installer settings menu press to confirm the settings Installer settings The system will restart Confirm Adjust Cancel OK Result...

Page 15: ...tion select Confirm layout and press Confirm layout Please confirm the system layout The system will restart and will be ready for first startup OK Cancel Confirm Adjust 5 The user interface re initia...

Page 16: ...d backup heater Backup heater EKMBUHCA3V3 can only be configured to be a 3V3 backup heater Unified backup heater EKMBUHCA9W1 can be configured in 4 ways 3V3 1 230 V 1 step of 3 kW 6V3 1 230 V 1st step...

Page 17: ...sensor connected to option box EK2CB07CAV3 INFORMATION You can only connect either the remote indoor sensor or the remote outdoor sensor Code Description A 2 2 F 6 D 04 PCC by digital inputs 0 No 1 Y...

Page 18: ...aximum modulation 0 C 10 C default 3 C Requires modulation to be enabled This is the value by which the desired leaving water temperature is increased or lowered INFORMATION When leaving water tempera...

Page 19: ...ature at the hot water taps INFORMATION There is a risk of space heating cooling capacity shortage comfort problem in case of frequent domestic hot water operation frequent and long space heating cool...

Page 20: ...thod Number of LWT zones Pump operation mode Power saving possible User interface location Options DHW pump External sensor Control box Option box Leaving water Main Additional Delta T source Room the...

Page 21: ...it The shut off valves are properly installed and fully open The pressure relief valve purges water when opened The minimum water volume is guaranteed in all conditions See To check the water volume i...

Page 22: ...sure the room temperature control the leaving water temperature control and the domestic hot water control are turned OFF via the user interface 3 Go to A 7 4 Installer settings Commissioning Actuato...

Page 23: ...es 2 Press for more than 5 seconds 8 Technical data A subset of the latest technical data is available on the regional Daikin website publicly accessible The full set of latest technical data is avail...

Page 24: ...actory setting of all switches OFF 4 Legend A1P Printed circuit board main A2P V3 only Printed circuit board service A2P W1 only Printed circuit board inverter A3P Printed circuit board noise filter A...

Page 25: ...hydro switch box Use normal kWh rate power supply for hydro switch box A1P Main PCB A2P Current loop PCB English Translation B1L Flow sensor E11H Flextube heater 15 6 W E12H Expansion vessel heater 50...

Page 26: ...ckup heater F1T F2T Thermal fuse backup heater F1U Fuse T 5 A 500 V backup heater option K1M Contactor backup heater step 1 English Translation K1R Relay backup heater step 1 K2M Contactor backup heat...

Page 27: ...om thermostat Only for KRTW wired room thermostat 2 core 3m included signal R2T External sensor floor or ambient Only for KRTETS External indoor thermistor Electricity pulse meter input 2 Electricity...

Page 28: ...4P522031 1 2018 01 Copyright 2018 Daikin 4P522031 1 0000000B...

Reviews: