8 Technical data

Installation manual

25

EBLQ+EDLQ011~W1
Daikin Altherma low temperature monobloc
4P522031-1 – 2018.01

R1, R2 (A2P) (W1
only)

Resistor

R1T

Thermistor (air)

R2T

Thermistor (discharge)

R3T

Thermistor (suction)

R4T

Thermistor (heat exchanger)

R5T

Thermistor (heat exchanger middle)

R6T

Thermistor (liquid)

R7T (W1 only)

Thermistor (fin)

R10T (V3 only)

Thermistor (fin)

RC (A4P)(V3
only)

Signal receiver circuit

S1NPH

Pressure sensor

S1PH

High pressure switch

TC (A4P)(V3 only)

Signal transmission circuit

V1R (A1P)(V3
only)

Power module

V1R~V2R (A2P)
(W1 only)

Power module

V2R~V3R (A1P)
(V3 only)

Diode module

V3R (A2P)(W1
only)

Diode module

V1T (A1P)(V3
only)

IGBT (Insulated Gate Bipolar Transistor)

X1M

Terminal strip

Y1E, Y3E

Electronic expansion valve

Y1S

Solenoid valve (4‑way valve)

Y3S

Solenoid valve (hot gas pass)

Z1C~Z9C

Noise filter (ferrite core)

Z1F~Z4F (A*P)
(V3 only)

Noise filter

Z1F~Z3F (A1P)
(W1 only)

Noise filter

Z4F

(A3P)(W1 only)

Noise filter

#

Field supply

*

Optional

Outdoor unit: hydro module

English

Translation

Compressor switch box

Compressor switch box

Control box

Control box

External outdoor ambient sensor
option

External outdoor ambient sensor
option

Hydro switch box supplied from
compressor module

Hydro switch box supplied from
compressor module

Hydro switch box

Hydro switch box

Indoor

Indoor

Normal kWh rate power supply

Normal kWh rate power supply

Only for normal power supply
(standard)

Only for normal power supply
(standard)

Only for preferential kWh rate
power supply (compressor)

Only for preferential kWh rate
power supply (compressor)

Outdoor

Outdoor

Use normal kWh rate power
supply for hydro switch box

Use normal kWh rate power
supply for hydro switch box

A1P

Main PCB

A2P

Current loop PCB

English

Translation

B1L

Flow sensor

E11H

Flextube heater (15.6 W)

E12H

Expansion vessel heater (50 W)

E13H

PHE heater (50 W)

E14H

Internal pipe heater 1 (50 W)

E15H

Internal pipe heater 2 (33 W)

F1U (A1P)

Fuse T5 A 250V

K*R (A1P)

Magnetic relay

M1P

Main supply pump

Q4DI

#

Earth leakage circuit breaker

R1T

Outlet water heat exchanger
thermistor

R3T

Refrigerant liquid side thermistor

R4T

Inlet water thermistor

R6T

*

External outdoor ambient sensor

S1L

Flow switch

TR1

Power supply transformer

X*A, X*Y (A1P, A2P)

Connector

X*M

Terminal strip

*:

Optional

#:

Field supply

Control box

English

Translation

BUH option

Backup heater option

Control box

Control box

DHW option

Domestic hot water option

DHW pump

Domestic hot water pump

Dual set point application (refer
to installation manual)

Dual set point application (refer
to installation manual)

Heat pump convector

Heat pump convector

Hydro switch box

Hydro switch box

NO valve

Normal open valve

Only for ***

Only for ***

Only for ext. sensor (floor or
ambient)

Only for external sensor (floor or
ambient)

Only for wired On/OFF
thermostat

Only for wired On/OFF
thermostat

Only for wireless On/OFF
thermostat

Only for wireless On/OFF
thermostat

Option box

Option box

Preferential kWh rate power
supply contact: 5 V DC detection
(voltage supplied by PCB)

Preferential kWh rate power
supply contact: 5 V DC detection
(voltage supplied by PCB)

A3P

*

On/OFF thermostat (PC=power
circuit)

A4P

*

Extension PCB (control, optional)

A5P

User interface PCB

A7P

*

Receiver PCB (wireless On/OFF
thermostat)

DS1 (A4P)

*

DIP switch

E4H

*

Booster heater (3 kW)

F1U

Fuse T 5 A 500 V

F1U (A4P)

Fuse T 2 A 250 V

F2B

*

Overcurrent fuse booster heater

F2U (A4P)

Fuse T 2 A 250 V for 3-way valve

K1A

Relay for heating

Summary of Contents for Altherma EBLQ014CAV3

Page 1: ...ow temperature monobloc English Installation manual Daikin Altherma low temperature monobloc EBLQ011CAV3 EBLQ014CAV3 EBLQ016CAV3 EBLQ011CAW1 EBLQ014CAW1 EBLQ016CAW1 EDLQ011CAV3 EDLQ014CAV3 EDLQ016CAV3...

Page 2: ...B C 500 250 100 A B C E 500 250 150 1000 500 500 D 500 500 D E 1000 500 B D 250 500 B D E 250 250 400 400 400 400 400 1000 150 150 150 150 150 150 150 1000 1000 1000 500 HD HU HD HU HB HU HD HU HB HU...

Page 3: ...sti za p edpokladu e jsou vyu v ny v souladu s na imi pokyny odpov daj n sleduj c m norm m nebo normativn m dokument m u skladu sa slijede im standardom ima ili drugim normativnim dokumentom ima uz uv...

Page 4: ...py the system settings from the first to the second user interface 14 5 1 4 To copy the language set from the first to the second user interface 15 5 1 5 Quick wizard Set the system layout after first...

Page 5: ...5 C in domestic hot water operation mode 3 2 Preparing water piping NOTICE In case of plastic pipes make sure they are fully oxygen diffusion tight according to DIN 4726 The diffusion of oxygen into t...

Page 6: ...m flow rate can be checked by way of the pump test check that the user interface does NOT display error 7H NOTICE When circulation in each or certain space heating loops is controlled by remotely cont...

Page 7: ...nd washers field supply as follows 150 6 2 0 350 3 4 5 3 5 5 a mm 2 6 1 5 6 M12 a Make sure not to cover the drain holes INFORMATION The recommended height of the upper protruding part of the bolts is...

Page 8: ...n places where strong wind can tilt the unit take following measure 1 Prepare 2 cables as indicated in the following illustration field supply 2 Place the 2 cables over the outdoor unit 3 Insert a rub...

Page 9: ...ng Prevent from freezing 5 C 10 15 10 C 15 25 15 C 20 35 20 C 25 25 C 30 NOTICE The required concentration might differ depending on the type of glycol ALWAYS compare the requirements from the table a...

Page 10: ...ter field supply indicates a pressure of 2 0 bar 5 Purge as much air as possible from the water circuit For instructions see 6 Commissioning on page 21 6 Refill the circuit until the pressure is 2 0 b...

Page 11: ...emove reposition the switch box and gain access to other components during service CAUTION Do NOT push or place redundant cable length in the unit 4 4 2 To connect the main power supply 1 Connect the...

Page 12: ...4C From the top a b PCB b 1 4D From the top centre a PCB b b 1 a Notch this part for the wiring to pass through with nippers etc b Secure the wiring to the front part of the casing using the wiring re...

Page 13: ...er NOT all settings are accessible via both methods If so the corresponding table columns in this chapter are set to N A not applicable Method Column in tables Accessing settings via the breadcrumb in...

Page 14: ...other settings 6 Push to confirm the modification of the parameter 7 At installer settings menu press to confirm the settings Installer settings The system will restart Confirm Adjust Cancel OK Result...

Page 15: ...tion select Confirm layout and press Confirm layout Please confirm the system layout The system will restart and will be ready for first startup OK Cancel Confirm Adjust 5 The user interface re initia...

Page 16: ...d backup heater Backup heater EKMBUHCA3V3 can only be configured to be a 3V3 backup heater Unified backup heater EKMBUHCA9W1 can be configured in 4 ways 3V3 1 230 V 1 step of 3 kW 6V3 1 230 V 1st step...

Page 17: ...sensor connected to option box EK2CB07CAV3 INFORMATION You can only connect either the remote indoor sensor or the remote outdoor sensor Code Description A 2 2 F 6 D 04 PCC by digital inputs 0 No 1 Y...

Page 18: ...aximum modulation 0 C 10 C default 3 C Requires modulation to be enabled This is the value by which the desired leaving water temperature is increased or lowered INFORMATION When leaving water tempera...

Page 19: ...ature at the hot water taps INFORMATION There is a risk of space heating cooling capacity shortage comfort problem in case of frequent domestic hot water operation frequent and long space heating cool...

Page 20: ...thod Number of LWT zones Pump operation mode Power saving possible User interface location Options DHW pump External sensor Control box Option box Leaving water Main Additional Delta T source Room the...

Page 21: ...it The shut off valves are properly installed and fully open The pressure relief valve purges water when opened The minimum water volume is guaranteed in all conditions See To check the water volume i...

Page 22: ...sure the room temperature control the leaving water temperature control and the domestic hot water control are turned OFF via the user interface 3 Go to A 7 4 Installer settings Commissioning Actuato...

Page 23: ...es 2 Press for more than 5 seconds 8 Technical data A subset of the latest technical data is available on the regional Daikin website publicly accessible The full set of latest technical data is avail...

Page 24: ...actory setting of all switches OFF 4 Legend A1P Printed circuit board main A2P V3 only Printed circuit board service A2P W1 only Printed circuit board inverter A3P Printed circuit board noise filter A...

Page 25: ...hydro switch box Use normal kWh rate power supply for hydro switch box A1P Main PCB A2P Current loop PCB English Translation B1L Flow sensor E11H Flextube heater 15 6 W E12H Expansion vessel heater 50...

Page 26: ...ckup heater F1T F2T Thermal fuse backup heater F1U Fuse T 5 A 500 V backup heater option K1M Contactor backup heater step 1 English Translation K1R Relay backup heater step 1 K2M Contactor backup heat...

Page 27: ...om thermostat Only for KRTW wired room thermostat 2 core 3m included signal R2T External sensor floor or ambient Only for KRTETS External indoor thermistor Electricity pulse meter input 2 Electricity...

Page 28: ...4P522031 1 2018 01 Copyright 2018 Daikin 4P522031 1 0000000B...

Reviews: