Technical data
A
subset
of the latest technical data is available on the regional Daikin website (publicly accessible). The
full set
of latest technical data is
available on the Daikin Business Portal (authentication required).
8.1
Piping diagram: Indoor unit
3D120613
R2T
R1T
B1PW
B1L
A
B
e
e
B
f
i
g
c
a
b
h
j
d
h
S1L
i
A
Water side
B
Field installed
a
Space heating water OUT
b
Water IN connection
c
Pump
d
Expansion vessel
e
Shut-off valve for service
f
Magnetic filter/dirt separator
g
Safety valve
h
Air purge
i
Drain valve
j
Backup heater
B1L
Flow sensor
B1PW
Space heating water pressure sensor
R1T
Thermistor (heat exchanger – water OUT)
R2T
Thermistor (backup heater – water OUT)
S1L
Flow switch
Screw connection
Flare connection
Quick coupling