4 Installation
Installation manual
12
EABH/X16DA+9W
Daikin Altherma – Low temperature split
4P556066-1 – 2018.10
4.4.8
To connect the alarm output
1
Connect the alarm output cable to the appropriate terminals as
shown in the illustration below.
X5M
A4P
X1M
YC Y1
YC Y1
Y2 Y3 Y4
X2M
X1M
7 9
a
a
Installation of EKRP1HB is required.
2
Fix the cable with cable ties to the cable tie mountings.
4.4.9
To connect the space cooling/heating ON/
OFF output
1
Connect the space cooling/heating ON/OFF output cable to the
appropriate terminals as shown in the illustration below.
X5M
A4P
X1M
YC Y1
YC Y2
Y2 Y3 Y4
X2M
X1M
7 9
a
a
Installation of EKRP1HB is required.
2
Fix the cable with cable ties to the cable tie mountings.
4.4.10
To connect the changeover to external
heat source
1
Connect the changeover to external heat source cable to the
appropriate terminals as shown in the illustration below.
X5M
A4P
X1M
YC Y1 Y2 Y3 Y4
X2M
X1M
X3
X4
X2M
X1
X2
L N
a
a
Installation of EKRP1HB is required.
2
Fix the cable with cable ties to the cable tie mountings.
4.4.11
To connect the power consumption digital
inputs
1
Connect the power consumption digital inputs cable to the
appropriate terminals as shown in the illustration below.
X5M
A8P
1 2 3 4 5
X801M
S6S
S7S
S8S
S9S
a
a
Installation of EKRP1AHTA is required.
2
Fix the cable with cable ties to the cable tie mountings.
4.4.12
To connect the safety thermostat (normal
closed contact)
1
Connect the safety thermostat (normal closed) cable to the
appropriate terminals as shown in the illustration below.
X5M
910
2
Fix the cable with cable ties to the cable tie mountings.