9

EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ
Daikin Altherma 3 R F+W
4P642728-1A – 2021.02

5.3

Possible screens: Overview

The most common screens are as follows:

+

a

OR

b

c

c2

c4

c1

c3

a

Home screen

b

Main menu screen

c

Lower level screens:

c1

: Setpoint screen

c2

: Detailed screen with values

c3

: Screen with weather-dependent curve

c4

: Screen with schedule

5.3.1

Home screen

Press  the 

  button  to  go  back  to  the  home  screen.  You  see  an

overview  of  the  unit  configuration  and  the  room  and  setpoint
temperatures.  Only  symbols  applicable  for  your  configuration  are
visible on the home screen.

6

1.6

bar

26 Feb 2019

22:19

55

21
35

j

e2

l

k1
k2

k3

45

d

e1

g3

g2

h1

g1

f

i2 i3

i4

h2

i1

a2

a1

e3

b c

Possible actions on this screen

Go through the list of the main menu.

Go to the main menu screen.

Enable/disable breadcrumbs.

Item

Description

a Domestic hot water

a1

Domestic hot water

a2

55

Measured tank temperature

(a)

Item

Description

b Disinfection / Powerful

Disinfection mode active

Powerful operation mode active

c Emergency

Heat pump failure and system operates in

Emergency

 mode or heat pump is forced off.

d Current date and time

e Smart energy

e1

Smart energy is available via solar panels or smart
grid.

e2

Smart energy is currently being used for space
heating.

e3

Smart energy is currently being used for domestic
hot water.

f

Space operation mode

Cooling

Heating

g Outdoor / quiet mode

g1

6

Measured outdoor temperature

(a)

g2

Quiet mode active

g3

Outdoor unit

h Indoor unit / domestic hot water tank

h1

Floor-standing indoor unit with integrated tank

Wall-mounted indoor unit

Wall-mounted indoor unit with separated tank

h2

Water pressure

i

Main zone

i1

Installed room thermostat type:

Unit operation is decided based on the ambient
temperature of the dedicated Human Comfort
Interface (BRC1HHDA used as room thermostat).

Unit operation is decided by the external room
thermostat (wired or wireless).

No room thermostat installed or set. Unit operation
is decided based on the leaving water temperature
regardless of the actual room temperature and/or
heating demand of the room.

i2

Installed heat emitter type:

Underfloor heating

Fancoil unit

Radiator

i3

21

Measured room temperature

(a)

i4

35

Leaving water temperature setpoint

(a)

j

Holiday mode

Holiday mode active

Summary of Contents for Altherma 3 R F+W EHBH04E 6V Series

Page 1: ...3 R F W EHBH04E 6V EHBH08E 6V EHBH08E 9W EHBX04E 6V EHBX08E 6V EHBX08E 9W EHVH04S U 18E 6V EHVH04S U 23E 6V EHVH08S U 18E 6V EHVH08S U 23E 6V EHVH08S18E 9W EHVH08S23E 9W EHVX04S18E 3V EHVX04S18E 6V EH...

Page 2: ...onfiguration wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best...

Page 3: ...appliance Cleaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do...

Page 4: ...n repaired WARNING Air purging heat emitters or collectors Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge...

Page 5: ...f you turn OFF space heating cooling operation C 2 Operation Space heating cooling room frost protection operation if enabled can still activate However for leaving water temperature control and exter...

Page 6: ...2 Outdoor ambient temperature Y1 Y4 Desired leaving water temperature a WD curve before changes b WD curve after changes c Slope d Offset Possible actions on this screen Select slope or offset Increas...

Page 7: ...ration The unit is in operation LED Mode Description Blinking red Malfunction A malfunction occurred See 8 1 To display the help text in case of a malfunction 418 for more information LCD screen The L...

Page 8: ...5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time date Hours Minutes Year Month Day Daylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet Acti...

Page 9: ...y Heat pump failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy...

Page 10: ...erature 2 Main zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leavin...

Page 11: ...ating cooling operation ON b Space heating cooling operation OFF Tank heating operation 55 21 35 45 c 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 5 4 2 To turn ON or OFF Spa...

Page 12: ...tions Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per month according...

Page 13: ...to produce hot water is at night because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time Initially the DHW tank temp...

Page 14: ...temperature control is active you can program the main zone schedule instead 1 Go to the schedule 2 optional Clear the content of the whole week schedule or the content of a selected day schedule 3 Pr...

Page 15: ...each character of the schedule name 4 To name the current schedule browse through the character list and confirm the selected character The schedule name can contain up to 15 characters 5 Confirm the...

Page 16: ...erature Go to the next temperature Confirm changes and proceed 5 9 3 Slope offset curve Slope and offset Define the weather dependent curve by its slope and offset Change the slope to differently incr...

Page 17: ...g 2 6 Main zone Cooling WD curve Additional zone Heating 3 5 Additional zone Heating WD curve Additional zone Cooling 3 6 Additional zone Cooling WD curve Zone Go to Tank Restriction Only available to...

Page 18: ...ndicated both in weight and CO2 equivalent Formula to calculate the quantity in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Please contact your installer for...

Page 19: ...the domestic hot water production and space heating For EHBH X The backup heater automatically takes over the heat load and the booster heater in the optional tank takes over the domestic hot water p...

Page 20: ...ater used in any type of building for domestic purposes LWT Leaving water temperature Water temperature at the water outlet of the unit 11 Installer settings Tables to be filled in by installer 11 1 C...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P642728 1A 2021 02 Copyright 2020 Daikin 4P642728 1 A 0000000 Verantwortung f r Energie und Umwelt...

Reviews: