7 Maintenance and service

Operation manual

18

EHBH/X04+08EA/EF + EHVH/X04+08S(U)18+23EA/EJ

Daikin Altherma 3 R F+W

4P642728-1A – 2021.02

▪ Use  a  weekly  schedule  for  your  normal  space  heating  or  cooling

needs. If necessary, you can easily deviate from the schedule:

▪ For  shorter  periods:  You  can  overrule  the  scheduled  room

temperature  until  the  next  scheduled  action. 

Example: 

When

you have a party, or when you are leaving for a couple of hours.

▪ For longer periods: You can use the holiday mode.

Tips about DHW tank temperature

▪ Use a weekly schedule for your normal domestic hot water needs

(only in scheduled mode).

▪ Program to heat up the DHW tank to a preset value (

Comfort

 =

higher  DHW  tank  temperature)  during  the  night,  because  then
space heating demand is lower.

▪ If  heating  up  the  DHW  tank  once  at  night  is  not  sufficient,

program to additionally heat up the DHW tank to a preset value
(

Eco

 = lower DHW tank temperature) during the day.

▪ Make  sure  the  desired  DHW  tank  temperature  is  NOT  too  high.

Example: 

After installation, lower the DHW tank temperature daily

by 1°C and check if you still have enough hot water.

▪ Program  to  turn  ON  the  domestic  hot  water  pump  only  during

periods of the day when instant hot water is necessary. 

Example:

In the morning and evening.

7

Maintenance and service

7.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance. You can find the
contact/helpdesk number via the user interface.

1

Go to [8.3]: 

Information

 > 

Dealer information

.

As end user, you have to:

▪ Keep the area around the unit clean.

▪ Keep the user interface clean with a soft damp cloth. Do NOT use

any detergents.

▪ Regularly check if the water pressure is above 1 bar.

Refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R32

Global warming potential (GWP) value: 675

NOTICE

Applicable  legislation  on 

fluorinated  greenhouse  gases

requires  that  the  refrigerant  charge  of  the  unit  is  indicated
both in weight and CO

2

 equivalent.

Formula  to  calculate  the  quantity  in  CO

2

  equivalent

tonnes:

  GWP  value  of  the  refrigerant  ×  total  refrigerant

charge [in kg] / 1000

Please contact your installer for more information.

WARNING: FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

WARNING

The  appliance  shall  be  stored  in  a  room  without
continuously  operating  ignition  sources  (example:  open
flames, an operating gas appliance or an operating electric
heater).

WARNING

▪ Do NOT pierce or burn refrigerant cycle parts.

▪ Do NOT use cleaning materials or means to accelerate

the  defrosting  process  other  than  those  recommended
by the manufacturer.

▪ Be  aware  that  the  refrigerant  inside  the  system  is

odourless.

WARNING

The  refrigerant  inside  the  unit  is  mildly  flammable,  but
normally  does  NOT  leak.  If  the  refrigerant  leaks  in  the
room  and  comes  in  contact  with  fire  from  a  burner,  a
heater, or a cooker, this may result in fire, or the formation
of a harmful gas.

Turn  off  any  combustible  heating  devices,  ventilate  the
room,  and  contact  the  dealer  where  you  purchased  the
unit.

Do  NOT  use  the  unit  until  a  service  person  confirms  that
the  part  from  which  the  refrigerant  leaked  has  been
repaired.

8

Troubleshooting

Contact

For  the  symptoms  listed  below,  you  can  try  to  solve  the  problem
yourself. For any other problem, contact your installer. You can find
the contact/helpdesk number via the user interface.

1

Go to [8.3]: 

Information

 > 

Dealer information

.

8.1

To display the help text in case of a
malfunction

In  case  of  a  malfunction,  the  following  will  appear  on  the  home
screen depending on the severity:

: Error

: Malfunction

You  can  get  a  short  and  a  long  description  of  the  malfunction  as
follows:

1

Press the left dial to open the main menu and go to

Malfunctioning

.

Result: 

A short description of the error and the error

code is displayed on the screen.

2

Press   in the error screen.

Result: 

A long description of the error is displayed

on the screen.

8.2

To check the malfunction history

Conditions: 

The user permission level is set to advanced end user.

1

Go to [8.2]: 

Information

 > 

Malfunction history

.

You see a list of the most recent malfunctions.

Summary of Contents for Altherma 3 R F+W EHBH04E 6V Series

Page 1: ...3 R F W EHBH04E 6V EHBH08E 6V EHBH08E 9W EHBX04E 6V EHBX08E 6V EHBX08E 9W EHVH04S U 18E 6V EHVH04S U 23E 6V EHVH08S U 18E 6V EHVH08S U 23E 6V EHVH08S18E 9W EHVH08S23E 9W EHVX04S18E 3V EHVX04S18E 6V EH...

Page 2: ...onfiguration wizard 20 11 2 Settings menu 20 1 About this document Thank you for purchasing this product Please Read the documentation carefully before operating the user interface to ensure the best...

Page 3: ...appliance Cleaning and user maintenance SHALL NOT be made by children without supervision WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do NOT operate the unit with wet hands Do...

Page 4: ...n repaired WARNING Air purging heat emitters or collectors Before you purge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge...

Page 5: ...f you turn OFF space heating cooling operation C 2 Operation Space heating cooling room frost protection operation if enabled can still activate However for leaving water temperature control and exter...

Page 6: ...2 Outdoor ambient temperature Y1 Y4 Desired leaving water temperature a WD curve before changes b WD curve after changes c Slope d Offset Possible actions on this screen Select slope or offset Increas...

Page 7: ...ration The unit is in operation LED Mode Description Blinking red Malfunction A malfunction occurred See 8 1 To display the help text in case of a malfunction 418 for more information LCD screen The L...

Page 8: ...5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time date Hours Minutes Year Month Day Daylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet Acti...

Page 9: ...y Heat pump failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy...

Page 10: ...erature 2 Main zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leavin...

Page 11: ...ating cooling operation ON b Space heating cooling operation OFF Tank heating operation 55 21 35 45 c 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 5 4 2 To turn ON or OFF Spa...

Page 12: ...tions Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per month according...

Page 13: ...to produce hot water is at night because the space heating demand is lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time Initially the DHW tank temp...

Page 14: ...temperature control is active you can program the main zone schedule instead 1 Go to the schedule 2 optional Clear the content of the whole week schedule or the content of a selected day schedule 3 Pr...

Page 15: ...each character of the schedule name 4 To name the current schedule browse through the character list and confirm the selected character The schedule name can contain up to 15 characters 5 Confirm the...

Page 16: ...erature Go to the next temperature Confirm changes and proceed 5 9 3 Slope offset curve Slope and offset Define the weather dependent curve by its slope and offset Change the slope to differently incr...

Page 17: ...g 2 6 Main zone Cooling WD curve Additional zone Heating 3 5 Additional zone Heating WD curve Additional zone Cooling 3 6 Additional zone Cooling WD curve Zone Go to Tank Restriction Only available to...

Page 18: ...ndicated both in weight and CO2 equivalent Formula to calculate the quantity in CO2 equivalent tonnes GWP value of the refrigerant total refrigerant charge in kg 1000 Please contact your installer for...

Page 19: ...the domestic hot water production and space heating For EHBH X The backup heater automatically takes over the heat load and the booster heater in the optional tank takes over the domestic hot water p...

Page 20: ...ater used in any type of building for domestic purposes LWT Leaving water temperature Water temperature at the water outlet of the unit 11 Installer settings Tables to be filled in by installer 11 1 C...

Page 21: ......