Removal Procedure
2.6
Removal of
Four Way Valve Coil
,
Solenoid Valve Coil
,
Electronic Expansion Valve Coil
and
Thermistor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Remove 1 screw of the
four way valve coil.
2
Remove one screw of
the solenoid valve coil.
3
Remove the electronic
expansion valve coil for
each room.
Place the thermistor so that
its end comes up to the end
of the presser spring.
4
Release the thermistor
presser spring, and
remove the discharge
pipe thermistor.
Be careful not to lose the
presser spring for the
discharge pipe thermistor.