125
Rule adding
Figure 4-69
2)
Double-click the rule you have just added to select measurement items and modify the
measurement name.
3)
Draw your rules.
Select
Measurement Items
as
Spot
, and you can click a position on the
surveillance image and a spot is formed.
Select
Measurement Items
as
Line
,
Rectangle
or
Ellipse
, and you can hold the
left mouse button to draw rules you need on the surveillance image.
Select
Measurement Items
as
Polygon
, and you can hold the left mouse button
to draw rules you need on the surveillance image. Right-click to end your drawing.
Select a rule you have drawn and click
Redraw Rule
. Then you can delete the rule and
draw a new one.
4)
Select the
Open Local Config
check box
and configure parameters. See Table 4-39.
Table 4-39
Parameter description of local configuration
Parameters
Description
Target Radiation
Coefficient
Radiation coefficient of targets that are shot by this Camera. Ranges
from 0.5 – 1.
Target Distance
Distance from the camera to targets that are shot. Ranges from 0m –
10000m.
Target Reflection
Temperature
Temperature of targets that are shot by this Camera. Ranges from
-50 °C to 327.7 °C.
5)
Enable the
Relay-out
check box and configure its parameters. See Table 4-40.