43
and the aircraft may even explode after calibration.
After calibration, view “1.11.5.1 Dashboard“, and turn corresponding buttons to confirm if
calibration is successful. After successful calibration, each parameter is about 1514.
Turning the endpoint, maximum value is 19XX while minimum value is 10XX.
The remote control can be normally used about 30s after calibration.
Select “Settings > Remote Control Settings> Joystick Calibration”.
Step 1
The system displays “Joystick Calibration” interface, as shown in Figure 0-28.
Figure 0-28
Move both the left and right joysticks back to the middle.
Step 2
Click “Start Calibration”.
Step 3
Turn two joysticks and turn to the maximum value end of each direction for several
Step 4
times.
Slide the rolling wheels on both sides, slide to the maximum value end of two directions
Step 5
for several times.
Click “Complete Calibration” after turning the rolling wheels and joysticks.
Step 6
1.13.2 Accelerometer Calibration
Pay attention to levelness and perpendicularity during calibration. Non-standard posture during
calibration will lead to abnormal flight and even explosion.
Select “Settings > General > Other > Accelerometer Calibration” to enter “Accelerometer
Calibration” interface, as shown in Figure 0-29.