28
Figure 2-37 Barrier control
Step 2
Configure parameters.
Table 2-12 Barrier control parameter description
Parameter
Description
Barrier Always Open
Select it, and enable the function of barrier always open. Configure the
period of barrier always open. The barrier will not close during the
defined period.
On
Select it to enable barrier control, and configuration.
Barrier Opening
Control
Triggers alarm through different modes, and remotely controls the
barrier opening and close.
●
Every Trigger (Camera)
: When the Camera captures any vehicle, it
outputs an open barrier signal.
●
Every Plate (Camera)
: When the Camera captures any plate, it
outputs an open barrier signal.
●
Allowlist Open (Camera)
: When the Camera captures vehicles that
are on the allowlist or conform to fuzzy matching, it outputs an open
barrier signal.
●
Order (Server)
: The Camera outputs an open barrier signal when it
receives a command from the platform.
●
Click
Manually Open
or
Manually Close
to manually control the
barrier.
You can set barrier opening control to
Allowlist Open (Camera)
, and
Order (Server)
at the same time.
Allowlist Open (Camera)
takes
priority.
Barrier Opening
Config
●
Relay-out
: Alarm linkage output port. You can select any one of the
3 ports.
●
Signal Duration
: The duration that the barrier opening or closing
signal lasts.
Barrier Closing
Config
Step 3
Click
Confirm
.
2.5.1.7 Configuring RS-485
You can configure RS-485 serial protocol of external devices. After configuration, you can set related
parameters of the device on the web client of the Camera.