79
Type
Operation
Configure to print zone alarm events: Enter
221 + 0 or 1 + 0 or 1.
Configure to print system events: Enter 222
+ 0 or 1 + 0 or 1 + 0 or 1 + 0 or 1 + 0 or 1 + 0
or 1 + 0 or 1 + 0 or 1.
Configure to print restored system events:
Enter 223 + 0 or 1 + 0 or 1 + 0 or 1 + 0 or 1
+ 0 or 1 + 0 or 1 + 0 or 1 + 0 or 1.
Configure to print operation events: Enter
224 + 0 or 1 + 0 or 1 + 0 or 1 + 0 or 1.
Configure to print restored operation
events: Enter 225 + 0 or 1 + 0 or 1 + 0 or 1 +
0 or 1.
Configure to print panic events: Enter 226 +
0 or 1 + 0 or 1.
Configure to print pulse events: Enter 227+
0 or 1 + 0 or 1.
Subsystem
Enable or disable subsystem: Enter 270 +
subsystem 0 or 1.
Add a zone to a subsystem: Enter 273 +
subsystem zone number.
Delete a zone from a subsystem: Enter 274
+ subsystem zone number.
Register
Configure device ID: Enter 321 + ID
number.
Configure server IP address: Enter 322 +
IP address.
Configure server port number: Enter 323 +
port number.
Alarm center
Configure server IP address: Enter 331 +
IP address.
Configure server port number: Enter 332 +
port number
Network (2G/4G)
Enable or disable 2G/4G: Enter 340 + 0 or 1.
Enable or disable dial: Enter 341 + 0 or 1.
Configure network: Enter 343 + 0 or 1 + 0
or 1.
Alarm receiving center
Enable or disable alarm receiving center:
Enter 360 + alarm receiving center No. + 0
or 1.
Configure transmission method for alarm
receiving center: Enter 361 + alarm
receiving center No. + transmission
method.