User’s Manual
68
3.6.17
Keypad
Description
Link or cancel to link subsystem of the keypad.
Command
Keypad
663
①
00
③
②
01
Table 3-63
Keypad
Number Description
1
The encoding address. The command operation means linking or cancelling to link
subsystem of the alarm keypad.
663: Link.
664: Cancel to link.
2
Keypad address: 00-31.
3
Subsystem number:01-08.
Example
The admin user links the keypad address 00 to the subsystem 1.
The admin user enters 6630001 under programming mode.
Press
Enter
.
3.6.18
Card Key Bindings
Description
Enable or disable card key bindings.
Command
665: Enable. 666: Disable.