User’s Manual
71
Number Description
1
The encoding address. The command operation means configuring arming function
for the keypad.
2
Keypad address: 00-31.
3
0: Disable.
1: Enable.
Example
The admin user enables the arming function for the keypad (address: 00).
The admin user enters 700001 under programming mode.
Press
Enter
.
3.6.22
Keypad RS-485 Address
Description
Modify keypad RS-485 address.
Command
Modify keypad RS-485 address
710
①
00
③
②
08
Table 3-66
Modify alarm keypad RS-485 address
Number Description
1
The encoding address. The command operation means modifying keypad RS-485
address.
2
Keypad address before modifying: 00-31.
3
Keypad address after modifying: 00-31.
Example
The admin user modifies the keypad address from 00 to 08.
The admin user enters 7100008 under programming mode.
Press
Enter
.