Local Basic Operation
229
Figure 4-177
Step 2 Configure parameters. See Table 4-49.
Table 4-49
Parameter
Description
Event Type
Click the corresponding tab to set different abnormality events.
HDD: Sets process method when there is a HDD event such as HDD error,
no HDD, no space. See Figure 4-176.
Network: Sets process method when there is a network event such as
disconnection, IP conflict, MAC conflict. See Figure 4-177.
Different series products support different event types. The actual product shall
prevail.
Enable
Check the box to enable the function
Less than
System generates an alarm once the HDD space is less than the threshold.
For
HDD No Space
type only.
Alarm Out
The alarm device (such as lights, sirens, etc.) is connected to the alarm output
port. When an alarm occurs, the NVR device transmits the alarm information to
the alarm device.
Latch
When the alarm ends, the alarm extended for a period of time. The time range is
from 0 seconds to 300 seconds.
Show
Message
Check box to enable a pop-up message in your local host PC.
Alarm
Upload
Select the check box. When an alarm occurs, the NVR device uploads an alarm
signal to the network (including the alarm center).
This function is for some series products only.
You need to set the alarm center first. For details, see "4.12.11 Alarm