background image

DAGON Lighting

 

SPM-12 – controller 

DMX-512 – 12 OUT DC / PWM

 

 

 

4

2. SPM-12 controller configuration.

 

 

The  SPM-12  controller  is  a  device  freely  programmable  by  the  user.  Configuration 

consists  of  entering  the  driver  control  3  digit  code  (000  to  999),  which  determine  the 
operation of the controller. To enter the codes 2 buttons have to be used marked as CODE and 
PLUS and also 2 signalization diodes – green and yellow, as shown in the Figure 1. 
The meaning off all steering codes is mention in table 1 on page 6 of this manual.

 

Typically,  correct  and  complete  configuration  of  the  driver  SPM-12  requires  to  type  a  few 
control codes. This is the correct action from the user part. 

 
 

2.1. Methods of entering the codes to SPM-12 controller. 

 

To enter the code to the driver SPM-12 button CODE need to be pressed. The green diode 

will light off and the yellow one will light on. 

 

Entering the first digit of code: 

 

  Button PLUS need to be press as many times as the first digit of code is from 0 to 9. 
  Every press is signalize by a short blinking of green diode. 
  After set in the first digit, button CODE need to be press one more time. 
  The yellow diode will blink (light off for half a second and light on again) 
  which is the signal to enter the second digit of code.

 

 

Entering the second digit of code: 

 

  Button PLUS need to be press as many times as the second digit of code is from 0 to 9. 
  Every press is signalize by a short blinking of green diode. 
  After set in the second digit button CODE need to be press one more time. 
  The yellow diode will blink and it is the signal to set in the third digit. 

 

Entering the third digit of code: 

 

  Button PLUS need to be press as many times as the third digit of code is from 0 to 9. 
  Every press is signalize by a short blinking of green diode. 
  After set in the third digit button CODE need to be press one more time. 
  The yellow diode will light off and the green one light on – this is the signal 
  that the code is ready. 
 

After entering the code SPM-12 controller passes for regular operation, and to control the 

outputs Q1-Q12 in the manner which is set out the current configuration – by control codes.

 

 

In order to enter another code, proceed similarly as described above. The same code can 

be entered multiple times, which has no negative influence to the operation of the controller. 

 

Not all the codes (available from range 000-999) are used. When set in the codes which 

has no function it will not change the work of controller. This kind of code is signalized as the 
incorrect code by a triple blinking of yellow diode just after set-in all three digits of code. 

 

Ale  set-in  codes  are  remembered  in  EEPROM  memory  of  SPM-12  controller.  Lack  of 

power doesn’t cause losing the settings made by CODE and PLUS buttons. 

 

If  any  time,  while  configuration,  the  buttons  CODE  and  PLUS  will  be  not  pressed  by  1 

minute, SPM-12 automatically stop configuration and goes to the regular work. 
 

Summary of Contents for SPM-12

Page 1: ...DMX 512 controller 12 OUT DC PWM MANUAL INSTRUCTION Firma DAGON 64 100 Leszno Jackowskiego 24 Street mob 00 48 664 092 493 dagon iadagon pl www iadagon pl www dagonlighting pl DAGON Lighting Product...

Page 2: ...X address SPM 12 driver 5 2 3 Description of configuration codes of SPM 12 6 2 4 Example configuration of the controller SPM 12 7 3 Safety and correct conditions of using SPM 12 controller 8 4 SPM 12...

Page 3: ...f power On the Figure 1 the proper way of wiring the power supply and receiver LED diodes to control SPM 12 is shown Remember to pick up the power cables of sufficient diameter relative to a flowing c...

Page 4: ...of code is from 0 to 9 Every press is signalize by a short blinking of green diode After set in the second digit button CODE need to be press one more time The yellow diode will blink and it is the si...

Page 5: ...of first digit of DMX 512 address Green diode will blink as many times as the first digit of DMX address is from 0 to 5 Than yellow diode blinks once light off for half a second and light on again wh...

Page 6: ...X controller it means one code form range 001 to 512 When user enter any code from 001 to 512 it will cause automatic change the previous value form this range and memorize new address od DMX in memor...

Page 7: ...dividual codes is described in Table 1 The demonstration effect for the code 631 is smoothly dimming and lightening of LEDs connected to the outputs Q1 Q12 in an alternate driver for the outputs of od...

Page 8: ...ects what may cause the stillness effect on the rotating equipment s which is light by impulse lights it may cause dangerous situation for life and healthy 4 SPM 12 Technical data Power supply 9 24V D...

Reviews: