Codes 

621

  and 

622

  activates  function  DIMMER  available  only  in  PWM  mode,  usually 

used for steering the LED brightness connected to outputs Q1- Q12. 
DIMMER  function  allows  for brightness regulation of all outputs at the same time by using 
only  one  DMX-512  channel,  and  activate  additional  13  DMX  channel  with  address

 

address DMX + 12

, where 

address DMX

 is code from 001..512 range – see above. 

When  the  signal  DMX-512  increased  for  code 

621

,  the  brightness  of  LED  will  also 

increased. 

When the signal DMX-512 increased for code 

622

, the brightness of LED will decreased. 

If  the  function  DIMMER  is  not  necessary  code 

620

  need  to  be  enter  to  turn  it  off  and 

release the 13 channel DMX. 
 

Codes 

630  to  635

  settle  the  way  of  reaction  SPM-12  controller  for  lack  of  DMX-512 

signal.  One  second  after  lack  of  DMX-512  signal  take  place  the  reaction  determine  by  the 
enter code. 

The  re-apperance  of  DMX-512  signal  at  the  inputs  DMX+  and  DMX-  an  immediate 

return  to  the  control  outputs  Q1-Q12  data  from  the  received  signal  DMX-512  (except when 
code 610 is entered forcing the driver SPM-12 to work without the DMX signal). 

The  way  of  response  of  SPM-12  driver  for  DMX  signal  loss  for  the  individual  codes  is 

described in Table 1. 
The  demonstration  effect  for  the  code 

631

  is  smoothly  dimming  and  lightening  of  LEDs 

connected  to  the  outputs  Q1-Q12  in  an  alternate  driver  for  the  outputs  of  odd  and  even 
numbers, and with the average brightness LEDs. 
 
Some combinations of input control codes are especially noteworthy, eg: 

 

-  Entering codes 610 and 630 will continuous disable the state outputs Q1-Q12 (regardless of 

DMX-512 signal), because after the reboot power all outputs of controller SPM-12 are reset, 
code  630  does  not  change  the  output  status,  and  the  code  610  prevents  receiving 
the DMX-512 signal; 

 

-  Entering  codes  610  and  633  will  generate  a  continuous  PWM  signal  at  the  outputs  of  the 

fulfillment of 20%, eg dim the LEDs connected to the outputs Q1-Q12; 

 

-  Entering  codes  612  forcing  the  work  of 

Q1-Q12  in  DC

  mode  should  not  be  link  with  631, 

633,  634  codes,  because  in  case  of  loss  of  DMX-512  signal  at  the  outputs  of  the  PWM 
waveform  will  appear,  which  may  cause  malfunction  of  receivers  designed  to  control  DC 
(ON / OFF), such as relay coils; 

 
 

2.4. Example configuration of the controller SPM-12: 

 

001 - address DMX = 1  (address of output Q1 = 1, address of output Q12 = 12) 
611 - outputs work Q1-Q12 in PWM mode 
621 - DIMMER active on channel number 13th - DMX 
631 - display effect is active while lack of  DMX-512 signal 

 

These 4 codes need to be set in into SPM-12 to ensure work in requested way. 
Sequence of entering the codes is optional. 
 

Summary of Contents for SPM-12

Page 1: ...DMX 512 controller 12 OUT DC PWM MANUAL INSTRUCTION Firma DAGON 64 100 Leszno Jackowskiego 24 Street mob 00 48 664 092 493 dagon iadagon pl www iadagon pl www dagonlighting pl DAGON Lighting Product...

Page 2: ...X address SPM 12 driver 5 2 3 Description of configuration codes of SPM 12 6 2 4 Example configuration of the controller SPM 12 7 3 Safety and correct conditions of using SPM 12 controller 8 4 SPM 12...

Page 3: ...f power On the Figure 1 the proper way of wiring the power supply and receiver LED diodes to control SPM 12 is shown Remember to pick up the power cables of sufficient diameter relative to a flowing c...

Page 4: ...of code is from 0 to 9 Every press is signalize by a short blinking of green diode After set in the second digit button CODE need to be press one more time The yellow diode will blink and it is the si...

Page 5: ...of first digit of DMX 512 address Green diode will blink as many times as the first digit of DMX address is from 0 to 5 Than yellow diode blinks once light off for half a second and light on again wh...

Page 6: ...X controller it means one code form range 001 to 512 When user enter any code from 001 to 512 it will cause automatic change the previous value form this range and memorize new address od DMX in memor...

Page 7: ...dividual codes is described in Table 1 The demonstration effect for the code 631 is smoothly dimming and lightening of LEDs connected to the outputs Q1 Q12 in an alternate driver for the outputs of od...

Page 8: ...ects what may cause the stillness effect on the rotating equipment s which is light by impulse lights it may cause dangerous situation for life and healthy 4 SPM 12 Technical data Power supply 9 24V D...

Reviews: