35
6. To remove high voltage capacitor.
(1) Remove two screws
1
which secure the
grounding ring terminal
2
of diode and capacitor
holder
3
.
(2) Remove capacitor holder
3
with capacitor
4
.
(3) Reverse the above steps for reassembly.
High voltage circuit wiring
7. To remove magnetron.
(1) Remove a screws
1
which secure guide air assy
2
and remove guide air assy
2
.
(2) Remove three screws
3
which secure the
magnetron
4
.
(3) Remove the magnetron
4
.
(4) Reverse the above steps for reassembly.