36
8. To remove fan motor assembly and guide wind.
(1) Remove screws
1
.
(2) Remove Guide wind Assy
(3) Remove Fan.
(4) Remove two screws
4
holding the fan motor
5
.
(5) Remove guide wind
2
.
(6) Reverse the above for reassembly.
9. To remove transformer.
(1) Remove four tapping screws
1
.
(2) Remove the transformer
2
.
(3) Reverse the above steps for reassembly.
CAUTION : Never install the magnetron without the metallic gasket plate which is packed with each magnetron to
prevent microwave leakage. Whenever repair work is carried out on magnetron, check the microwave
leakage. It shall not exceed 1mW/cm
2
.