1. CIRCUIT CHECK PROCEDURE
1) Low Voltage Transformer (DMR-604FS) Check.
The low voltage transformer is located on the P.C.B.
Measuring condition: Input voltage: 230V
Frequency: 50Hz
2) Voltage Check
KEY CHECK POINT
CHECK METHOD
44
PRINTED CIRCUIT BOARD
NOTE 1: Secondary side voltage of the low voltage transformer changes in proportion to fluctua-
tion of power source voltage.
NOTE 2: The allowable tolerance of the secondary voltage is within ±5% of norminal voltage.
NOTE: Each measure point must be measured with GND points.
6–7
24V
30V
8–10
2.4V
2.5V
Voltage
Terminal
LOAD
NO LOAD
NO.
CHECK POINT
REMARK
1
IC1 PIN 6, 10, 11
-5VDC
2
IC1 PIN 1
-20VDC
3
IC1 PIN 22
4
IC1 PIN 8 OR 9
5
DP1 PIN 1 & 25
2.4VAC (DISPLAY FILAMENT VOLTAGE)
1
MP1
DC -5V±0.25
Replace ZD2, EC1, EC2
NO LOAD
2
MP2
DC -30V±1.0
Replace R21, ZD3
NO LOAD
3
MP3
DC-27V±1.0
Replace R21, R22, EC5
NO LOAD
NO.
MEASURE POINT
Fig. 6
WAVE FORM
REMEDY
REMARK