(TROUBLE 6) Micrwave Output power is low .
First of all, check if output power is really low following “measurement
of the microwave output power” on page 35.
34
Check
Result
Cause
Cause
Customer
education
Check the power
source voltage
with magnetron
oscillating
Condition
Output
power is low.
Lower than
207 volts
Descrease in
power source
voltage
Normal
Replace
Check the timing
periods of the
RELAY “1” coil
Abnormal
NOTE 3
Defective touch
control circuit
Replace depending
on the result of
output test
Normal
Aging change
of
magnetron
NOTE 2:
The following chart shows the timing periods of the RELAY “1”.
NOTE 3:
Interlock monitor switch must be replaced when fuse is blown out.
POWER
0
1
2
3
4
5
6
7
8
9
HI
RELAY “1” ON TIME
0
3 (Seconds)
5
8
11
14
17
20
23
26
29
RELAY “1” OFF TIME
29
26 (Seconds)
24
21
18
15
12
9
6
3
0
Summary of Contents for KOG-361Q
Page 38: ...37 WIRING DIAGRAM GERMANY...
Page 39: ...38 WIRING DIAGRAM...
Page 47: ...Fig 6 Measurement Point 46...
Page 50: ...2 COMPONENT INFORMATION 1 Transistor 2 Diode and Zener Diode 49...
Page 51: ...3 PRINTED CIRCUITS BOARD 50...
Page 52: ...4 P C B CIRCUIT DIAGRAM 51...
Page 56: ...55...