• Disconnect the oven from the power supply.
• You can test continuity of safety interlocks and monitor switch by using switch tester or ohmmeter.
• The switch operation is checked by the lamp on/off of resistance zero/unlimited.
• The sequence of check is interlock monitor switch; primary and secondary interlock switches check.
• Make circuits like Fig. a, Fig. b, Fig. c for tests.
43
SAFETY INTERLOCK CONTINUITY TEST
1) In case of interlock monitor check.
(Lamp on or zero resistance)
(ohmmeter)
– Fig. a –
Condition: 1) Door is opened.
2) Common terminal of the monitor
switch disconnected.
3) In case of secondary interlock switch.
(ohmmeter)
Condition: 1) Door is closed.
2) In case of primary interlock check.
(Lamp on or zero resistance)
(ohmmeter)
– Fig. b –
Condition: 1) Door is closed.
* (Schematic diagarm of S/W tester)
Summary of Contents for KOG-361Q
Page 38: ...37 WIRING DIAGRAM GERMANY...
Page 39: ...38 WIRING DIAGRAM...
Page 47: ...Fig 6 Measurement Point 46...
Page 50: ...2 COMPONENT INFORMATION 1 Transistor 2 Diode and Zener Diode 49...
Page 51: ...3 PRINTED CIRCUITS BOARD 50...
Page 52: ...4 P C B CIRCUIT DIAGRAM 51...
Page 56: ...55...