SYMBOL
RD
BL
BK
WH
GY
COLOR
RED
BLUE
BLACK
WHITE
GRAY
(2) Secondary interlock switch and interlock monitor switch
When the door is closed, the hook pushes the push lever down ward, and push lever presses the
button of the interlock monitor switch to bring it under “off”, condition and presses the button of the
secondary interlock switch to bring it under “on”, condition.
Adjustment 2.
Interock monitor switch
When the door is closed, the interlock monitor switch should be opend before other switches close.
When the door is closed, the interlock monitor switch should be closed after other switches open.
Secondary interlock switch
The movement of the switch button should exceed 1.2mm measured at the top of the button.
(3) Adjustment steps
a) Loosen the two mounting screws.
b) Adjust interlock switch assembly position.
c) Confirm the gap (1.2mm) described above.
d) Make sure that push lever moves smoothly adjustments is completed.
e) Completly tighten the two mounting screws.
(4) Interlock switch replacement
Whenever safety interlock switches are replaced:
1) Refer to the following diagram.
2) Check the connection of monitor switch after replacement.
3) Perform the electrical continuity check of interlock switches and microwave emission test men-
tioned in this manual.
20
NOTE:
Microwave emission test should be performed after adjusting interlock mechanism. If the
microwave emission exceed 4mW/cm
2
, readjust interlock mechanism.
Summary of Contents for KOG-361Q
Page 38: ...37 WIRING DIAGRAM GERMANY...
Page 39: ...38 WIRING DIAGRAM...
Page 47: ...Fig 6 Measurement Point 46...
Page 50: ...2 COMPONENT INFORMATION 1 Transistor 2 Diode and Zener Diode 49...
Page 51: ...3 PRINTED CIRCUITS BOARD 50...
Page 52: ...4 P C B CIRCUIT DIAGRAM 51...
Page 56: ...55...