8. OPERATING GUIDE
The operational steps are pasted above the fuel tank, . please operate as per the instructions.
Unit grounding
Shift the machine outdoors, use
the grounding terminal connection
wire to ground to earth. One end
of the wire is pressed below the
butterfly nut on the unit, screw it
up tightly, and the other end is
connected with the metal rod that
is inserted into the ground.
Pre-operational
Add engine oil
Unscrew the oil dip stick, add
engine oil SAE10W/30 (oil require-
ments may vary if operating in
extreme temperatures, refer
above table). Fill the oil to the top
of the thread (indicated as
"Correct Oil Level" above).
If oil is spilt wipe off machine to
avoid fire hazard and from the
ground to avoid slipping.
Open the fuel fill cap and fill with a
Ethanol Free 91 octane gasoline
(95 and 98 octane may be used).
The fuel level position will be
displayed on the indicator opposi-
te the fuel cap. When filling the
tank the maximum fuel position
shall not exceed the inner strainer
of the Fuel tank as indicated
above.
Warning:
keep away from any
possible ignition source when
filling gasoline; do not fill the fuel
tank while the generator is in
operation.
Connect electric battery
(electrical starting only)
Connect the battery, red for
positive terminal and green for the
negative terminal and make sure
you tighten the nuts. Pay attention
and avoid contact between positi-
ve and negative terminal to elimi-
nate the chance of short circuit.
Make sure you place the rubber
protective covers over the termi-
nals.
Summary of Contents for GDA Series
Page 42: ...14 ELECTRICAL SCHEMATIC DIAGRAM 1 RECOIL START MONOPHASE 41...
Page 43: ...ELECTRICAL SCHEMATIC DIAGRAM 2 ELECTRIC START MONOPHASE 43...
Page 44: ...ELECTRICAL SCHEMATIC DIAGRAM 3 ELECTRIC START MONOPHASE 44...
Page 45: ...ELECTRICAL SCHEMATIC DIAGRAM 4 RECOIL START MONOPHASE 45...
Page 46: ...ELECTRICAL SCHEMATIC DIAGRAM 5 ELECTRIC START THREE PHASE 46...
Page 47: ...ELECTRICAL SCHEMATIC DIAGRAM 6 RECOIL START THREE PHASE 47...