58
1) Remove residual refrigerant more than 5 minutes later after
turning off the refrigerator. ( If not, compressor oil may leak inside.)
2) Remove retained refrigerant slowly by cutting first high pressure
side (drier part) with a nipper and then cut low pressure side.
1. Removal of residual
refrigerant.
Precautions
Items
8-3. Practical Work for Heavy Repair
* When replacing a drier:
Weld
①
and
②
parts by blowing nitrogen (0.1~0.2kg/cm2) to high
pressure side after assembling a drier.
* When replacing a compressor:
Weld
③
and
④
parts by blowing nitrogen to the low pressure side.
Note) For other parts, nitrogen blowing is not necessary because it
does not produce oxidized scales inside pipe because of its short
welding time.
2. Nitrogen blowing
welding.
※
KEYPOINTING
Welding without nitrogen blowing produces oxidized scales inside
a pipe, Which affect on performance and reliability of a product.
Process tube
Compressor
Evaporator
Dryer
High Pressure side
Low pressure
side
Suction tube
Discharge tube
Condenser
Hot Pipe
Process tube
Compressor
Evaporator
Dryer
High Pressure side
Low pressure
side
①
Condenser
②
③
④
Hot Pipe
Summary of Contents for FRS-20BD
Page 4: ......
Page 5: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 33: ...32 5 1 Wiring Diagram 5 DIAGRAM FRS 20BD 24BD Basic Model...
Page 34: ...33 FRS 20DD FD 24DD FD Dispenser Model...
Page 66: ......
Page 67: ......
Page 69: ...68 9 5 Dispenser Water Flow Dispenser Models Only...
Page 70: ...CABINET 69 10 EXPLODED VIEW 10 1 FRS 20BD 24BD Basic Model...
Page 71: ...EXPLODED VIEW MECH ROOM 70...
Page 72: ...EXPLODED VIEW R Room 71...
Page 73: ...72 EXPLODED VIEW F ROOM...
Page 74: ...73 EXPLODED VIEW F DOOR...
Page 75: ...74 EXPLODED VIEW R DOOR...
Page 81: ...EXPLODED VIEW 10 3 FRS 20DD FRS 24DD Dispenser Only CABINET 80...
Page 82: ...EXPLODED VIEW MECH ROOM 81...
Page 83: ...EXPLODED VIEW R Room 82...
Page 84: ...83 EXPLODED VIEW F ROOM...
Page 85: ...EXPLODED VIEW F Door 84...
Page 86: ...85 EXPLODED VIEW R Door...
Page 92: ...EXPLODED VIEW 10 5 FRS 20FD FRS 24FD Dispenser Homebar CABINET 91...
Page 93: ...EXPLODED VIEW MECH ROOM 92...
Page 94: ...EXPLODED VIEW R Room 93...
Page 95: ...94 EXPLODED VIEW F ROOM...
Page 96: ...EXPLODED VIEW F Door 95...
Page 97: ...96 EXPLODED VIEW R Door...