26
INPUT
CONTROL OBJECT
CONTENTS
REMARKS
Temperature Control Buttons
4-10. Filter information & Function to adjust the amount of water
( Dispenser Models Only )
88 Display Custom LED
Filter information
1. Filter Exchange Information : Record a real-time from the point of power input.
- The filter is normal for 6 months after the first installation.
- When the time comes to change or reset, press the WATER FILTER RESET button for 5 seconds.
2. Function of display of filter change time.
[step1] Press CRUSHED ICE button 5 times while pushing WATER button at the same time.
[step2] Press SUPER FREEZER button 5 times while pushing FREEZER SET button.
[step3] Press FREEZER SET button 6 times successively. (Fi-Lt is display)
[step4] Remaining time is display if DISPENSER button press.
( ex, 40 12 means that 4012minutes remains until the filter exchange. )
[END] Push RESET WATER FILTER or it is reset after 4 minutes.
Adjust the amount of Water
[step1] Press CRUSHED ICE button 5 times while pushing WATER button at the same time
.
[step2] Press SUPER FREEZER button 5 times while pushing FREEZER SET button.
[step3] Press FREEZER SET button 5 times successively. (P100 is display.)
- Initial setting P100 means 86cc water supply.
[step4] Adjust the amount of water
- If the amount is less than P100, press SUPER REFRIGERATOR button.
: P101 ( 87cc ), P102 ( 88cc ), P103 ( 89cc )…
- If the amount is more than P100, press REFRIGERATOR SET button.
: P99 ( 85cc ), P98 ( 84cc ), P97 ( 83cc )…
[END] Push RESET WATER FILTER or it is reset after 4 minutes.
Summary of Contents for FRS-20BD
Page 4: ......
Page 5: ......
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ......
Page 10: ......
Page 11: ......
Page 12: ......
Page 33: ...32 5 1 Wiring Diagram 5 DIAGRAM FRS 20BD 24BD Basic Model...
Page 34: ...33 FRS 20DD FD 24DD FD Dispenser Model...
Page 66: ......
Page 67: ......
Page 69: ...68 9 5 Dispenser Water Flow Dispenser Models Only...
Page 70: ...CABINET 69 10 EXPLODED VIEW 10 1 FRS 20BD 24BD Basic Model...
Page 71: ...EXPLODED VIEW MECH ROOM 70...
Page 72: ...EXPLODED VIEW R Room 71...
Page 73: ...72 EXPLODED VIEW F ROOM...
Page 74: ...73 EXPLODED VIEW F DOOR...
Page 75: ...74 EXPLODED VIEW R DOOR...
Page 81: ...EXPLODED VIEW 10 3 FRS 20DD FRS 24DD Dispenser Only CABINET 80...
Page 82: ...EXPLODED VIEW MECH ROOM 81...
Page 83: ...EXPLODED VIEW R Room 82...
Page 84: ...83 EXPLODED VIEW F ROOM...
Page 85: ...EXPLODED VIEW F Door 84...
Page 86: ...85 EXPLODED VIEW R Door...
Page 92: ...EXPLODED VIEW 10 5 FRS 20FD FRS 24FD Dispenser Homebar CABINET 91...
Page 93: ...EXPLODED VIEW MECH ROOM 92...
Page 94: ...EXPLODED VIEW R Room 93...
Page 95: ...94 EXPLODED VIEW F ROOM...
Page 96: ...EXPLODED VIEW F Door 95...
Page 97: ...96 EXPLODED VIEW R Door...