8
FEATURE
FUNCTIONAL PRINCIPLE
1
The micom can remember the time from the begining of drain to reset point when the pressure switch reaches to
“OFF” point
2
In case of continuous draining, residual drain time is determined by micom.
Draining time as a whole = D + 90
Residual drain time.
The time remembered by micom.
FUNCTIONAL PRINCIPLE
Bubble Motor supplies the air from the bottom of outer tub to the inner space of Pulsator Agitator, the air is dispersed
by the rotation of Pulsator Agitator. Air-bubble is created by the centrifugal force, and rises up.
Draining
Good draining
The washer begins spin process after drainage.
condition
Bad draining
Draininig time is prolonged.
No draining
Program is stopped and gives the alarm.
Drain Time
Movement of the Program
Less than
Continue draining
15 minutes
More than
Program stops and gives the alarm with
blinked on display lamp.
15 minutes
Functional Principle of Bubble Washing Machine
ACROSS SECTION
Automatic Drainning time Adjustment
This system adjusts the draining time automatically according to the draining condition.
Air bubble
Tub
Outer tub
Pulsator Agitator
Summary of Contents for DWF-200AS
Page 1: ...Service Manual Model DWF 200AS Auto Washer S M No WF200AS001 Oct 2003...
Page 29: ...APPENDIX 28 WIRING DIAGRAM Wiring Diagram Pump Non Bubble Multi Valve 110 127...
Page 30: ...29 WIRING DIAGRAM Wiring Diagram Pump Non Bubble Multi Valve 110 127...
Page 31: ...30 WIRING DIAGRAM Wiring Diagram Non Pump Non Bubble 220 240...
Page 32: ...31 WIRING DIAGRAM Wiring Diagram Pump Bubble Multi Valve 220 240...
Page 33: ...PARTS DIAGRAM 32 PARTS DIAGRAM...
Page 34: ...33 PARTS DIAGRAM...
Page 35: ...34 PARTS DIAGRAM...
Page 36: ...35 PARTS DIAGRAM...