background image

GLOSSARY

An -Crush Gap

This is the small sec on of travel near the end of the door’s closing cycle. If the operator 

receives a trigger in this sec on of travel, the door will reopen to prevent possible damage 

or injury.

Auto Close 

Func on

When set, this func on will enable automa c closing of the garage door a er a set period 

of  me.

Balanced Door

When the force required to open the garage door is equal to the force required to close 

the garage door.

Control Board

The main electronic circuit board housed inside the operator.

Courtesy Light

The light, built into the operator Control Card, which switches on during each door opera on

and can also be operated by pressing a programmed bu on on a remote control.

Door Balance

The even distribu on of the doors opening and closing forces.

Drive Channel

The steel channel housing the Chain, Li ing Assembly and Manual Release Mechanism

Fuse

A removable electronic component on the Control Card that protects the Control Card 

from damage in the case of severe forces being applied.

Infrared Safety 

Beams

Op onal electronic sensors which prevent the garage door from closing if the infrared 

beam, being transmi ed between the sensors, is blocked, indica ng an obstruc on.

LED Display

Electronic alphanumeric display on the operator used to assist with programming and 

fault finding.

Lockout

An electronic security feature that will prevent the door from receiving a trigger while the 

func on is ac ve.

Manual Release 

Mechanism

The lever assembly that is used to place the garage operator into manual mode, allowing 

for the garage door to be operated manually.

Obstacle 

Sensing

The detec on of an obstacle causing the mo on of the door to be impeded through the 

processing of algorithms in the garage door operator’s so ware.

Onboard 

Receiver

An integrated part of the Control Card which receives the signal from the Remote Control 

to trigger of the operator.

Ramp Down

Process of the operator slowing down the door’s travel speed towards the end of the 

door’s travel.

Remote Control

The hand held device used to ac vate the opening and closing of the operator.

Remote Bu on

One of several bu ons on a remote control used to ac vate various func ons.

Solar Panel

An op onal device connected directly to the Control Card to make use of sun energy 

instead of a buildings mains supply for charging the operator's ba ery.

Transformer

An external device connected to the buildings mains supply via a plug point that reduces 

the mains voltage to a safe voltage to charge the operators ba ery.

4

21

4.

Status Output (auxiliary)

The Status output is used to provide feedback from the operator on the current posi on of the Trolley on the 

Drive Channel and the mains supply status. Most commonly used for the Status Output is an LED, connected to 

the operator. The LED can be placed in a convenient loca on for ease of use.

It is important to understand that the Status Output only indicates the opera onal status of the operator and 

not the door. To explain, imagine the door is closed and the LED indicates that the operator is closed. The door 

is then placed in manual mode and opened manually, however the Trolley has not moved and remains in the 

closed posi on, the LED will con nue to indicate that the status of the operator as closed. When the door is 

reconnected to the Li ing Bracket (placed back in automa c mode), the status of both the door and operator 

will be closed.                                                          

Refer to ‘Se ng Auxiliary Output....Menu 5’ for programming.

LUX DC12

Control Board

 

2K7 

Resistor

LED

+

ve

-

ve

Open Collector 

Harness

(Double Wire)

Code: SA004

Resistor & LED not included.

5.

Low Ba ery Output (auxiliary)

This output will provide indica on when the ba ery is low. An LED or a GSM transmi er can be used.

Refer to ‘Se ng Auxiliary Output....Menu 5’ for programming.

LUX DC12

Control Board

 

2K7 

Resistor

LED

+

ve

-

ve

Open Collector 

Harness

(Double Wire)

Code: SA004

Resistor & LED not included.

 

GSM Module

INPUT

COM

Open Wire 

Connector

(Single Wire)

Code: SA044

 

OR

LED

OPERATOR & MAINS STATUS

ON

The operator/door is open

OFF The operator/door is closed and the 

mains is off.

BLINK The operator/door is closed and the 

mains is on.

REV

LIMITS

AUX LOCK 12V TRIG INF GND 

Power

Input

REV

LIMITS

AUX LOCK 12V TRIG INF GND 

Power

Input

6.

Trigger Output (auxiliary)

The Trigger Output is used to 

trigger other external devices at 

the same  me that the door 

operator is triggered. These 

devices can include buzzers 

inside the house which sound 

when the garage door is 

triggered. Another example is 

the switching on of lights or the 

deac va on of the home alarm 

by triggering a Pulse Stretcher.

Refer to ‘Se ng Auxiliary 

Output....Menu 5’ for 

programming.

NO

COM

DACE

Relay Module

Code: SA001

TRIGGER

GND

External 

Trigger

 

LUX DC12

Control Board

REV

LIMITS

AUX LOCK 12V TRIG INF GND 

Power

Input

Summary of Contents for LUX DC12

Page 1: ...the operator such as a transformer ba ery or beams warranty informa on regarding products may be found in the installa on guide pertaining to each product This warranty explicitly only covers the repa...

Page 2: ...wo of the remote bu ons simultaneously This will reduce the risk of accidentally ac va ng the Lockout func on ES Encoder Stop Fault Obstruc on Cause The operator has stalled This could be as a result...

Page 3: ...ers The advanced engineering and high quality construc on of each DACE product we build is something of which we are proud The LUX DC12 garage operator is packed with features to bring you convenience...

Page 4: ...energy instead of a buildings mains supply for charging the operator s ba ery Transformer An external device connected to the buildings mains supply via a plug point that reduces the mains voltage to...

Page 5: ...Board DuraOp cs Wireless Safety Beams REV LIMITS AUX LOCK 12V TRIG INF GND NO GND COM 12V 24V NC FET Power Input Cau on When ng a Magne c Lock to the door no NOT use the power from the operator as th...

Page 6: ...AYOUT CONTROL BOARD LAYOUT REV LIMITS AUX LOCK 12V TRIG INF GND Inputs Outputs Power Input 12 18V AC or 17 22V DC Solar ve ve Ba ery Cables Motor Wire Red Motor Wire Black Blue 20A Fuse Motor DBUS Inp...

Page 7: ...you to the Programming Menu Pr R c SET p r SET b c SET L E 18 L o SET 1 Ensure the ba ery is connected to the Operator 2 Press the SET bu on to enter the Programming Menu Pr 3 Press the DOWN bu on un...

Page 8: ...5 Press the DOWN bu on un l Lt Light is visible 6 Press and hold the remote bu on that is to be used to turn the operator light on and o Do not use the same bu on that was programmed to trigger the op...

Page 9: ...enu Pr 3 Press the DOWN bu on un l the Remote Menu rc is visible 4 Press the SET bu on to enter the Remote Menu The display will change to LE Learn 5 To program a remote press and hold the remote bu o...

Page 10: ...hts or bypass alarm passives when entering the garage Press the SET bu on to enter the AL menu Press the UP or DOWN bu ons to scroll through the me op ons T0 to T9 Press the SET bu on to select the de...

Page 11: ...re is free movement of the Li ing Assembly on the Drive Channel Li the door s manually to various heights and ensure that the door s do not close under their own weight If they do then it will be nece...

Page 12: ...ng the door will stop brie y and then reopen to the fully open posi on If the door is opening and it is stopped within 30cm of the fully closed posi on it will con nue opening when it receives the nex...

Reviews: