background image

12

Programming Remotes

:

The Circuit Board has a built in receiver and the remotes, supplied as part of the operator kit, will have already been 

programmed to the operator at the factory. 

To add addi onal remotes (up to 64) refer to ‘Programming Remotes’ 

on page 16

.

In addi on to triggering the operator to open and close, remotes can be programmed with the following features:

Addi onal opening & closing bu ons:

Each remote can be programmed with mul ple open and close bu ons. An example of this feature is 

programming one bu on to open & close the garage door and a second bu on to not only operate the door 

but also to open and close a gate or switch on security lights.

Remote Holiday Lockout:

Any bu on (or mul ple bu ons) on a remote can be programmed to enable or disable the Holiday Lockout 

feature. When ac vated, the display on the operator will change to 

LO

. Placing the controller into Holiday 

Lockout will prevent any remote from ac va ng the operator un l Holiday Lockout is deac vated. This 

feature is useful to prevent any members of staff or contractors from entering the garage while the owners 

are away. 

Courtesy Light Opera on

:

The operator has a built in LED light and whenever the operator is ac vated, this Courtesy Light will switch on for a 

period of 5 minutes. During a power failure, however, the Courtesy Light will only remain on for a period of 1 

minute.
In addi on to the standard Courtesy Light opera on, the built in LED light can also be switched on and off using a 

remote control bu on, without ac va ng the operator. To achieve this, a dedicated bu on on the remote must be 

programmed to the operator. Pressing this designated bu on on the remote will ac vate the light for a period of 

one hour, unless it is switched off using the same bu on again.
 

An  Crush Gap

:

The following will happen if the operator receives a trigger from a remote (or the bu ons on the operator) while the 

door is already in mo on: 

If the door is closing, the door will stop briefly and then reopen to the fully open posi on.

If the door is opening and it is stopped within ±30cm of the fully closed posi on, it will con nue opening when it 

receives the next trigger to prevent it from closing on a child or animal.

If the door is opening, and it is stopped further than ±30cm from the closed posi on, the door will start to close 

when it receives the next trigger.

Door opera on during low ba ery and power fail condi ons

:

The operator will flash an 

Lb

 (Low Ba ery) error message due to excessive opera ons, long power failure or a 

damaged ba ery. 
While the 

Lb

 condi on persists, the door will not close automa cally. This is to prevent a person from being locked 

out of the garage. The door will have to be closed manually by releasing the Manual Release Mechanism.
Note: If the door is stopped during a power failure while it is closing, it will not automa cally reverse back open.

Auto Close Func on

:

The operator can be programmed to automa cally close the door a er a programmed period of  me. Auto Close 

can only be ac vated if Safety Beams have been installed. When enabling the Auto Close func on the Safety Beam 

func on will automa cally be enabled.

During a power failure the courtesy light will switch off a er one minute, even if the dedicated light bu on is 

pressed.

The An  Crush Gap is the 30cm space towards the end of the door closing cycle, before the door is fully 

closed. This is a built in safety feature to prevent the entrapment of people or animals by the door. 

Press the 

SET

 bu on to ac vate the Programming Menu, use the UP and DOWN bu ons to navigate through the 

menu. 

To exit the menu, arrow down to the EXIT prompt (

bc

) and press the 

SET

 bu on.

PROGRAMMING MENU

SETTING THE PHYSICAL OPEN & CLOSE LIMITS

Programming Menu 

(2) Se ng the Opening & Closing Force 

(1) Se ng the Open and Close Limits 

(3) Enable or Disable Safety Beams 

(4) Se ng Auto Close 

(5) Se ng Auxiliary Output 

(6) Enable or Disable Electric/Magne c Lock 

(7) Programming Remotes 

(8) Factory Reset 

Exit Menu 

Press 

SET 

to enter 

the Programming 

Menu.

To exit the 

Programming 

Menu, press 

SET

 at 

the 

bc

 prompt.

L i 

F o 

b E 

A C 

A U 

l C 

r c 

F r 

b c 

P r 

13

Summary of Contents for LUX DC12

Page 1: ...the operator such as a transformer ba ery or beams warranty informa on regarding products may be found in the installa on guide pertaining to each product This warranty explicitly only covers the repa...

Page 2: ...wo of the remote bu ons simultaneously This will reduce the risk of accidentally ac va ng the Lockout func on ES Encoder Stop Fault Obstruc on Cause The operator has stalled This could be as a result...

Page 3: ...ers The advanced engineering and high quality construc on of each DACE product we build is something of which we are proud The LUX DC12 garage operator is packed with features to bring you convenience...

Page 4: ...energy instead of a buildings mains supply for charging the operator s ba ery Transformer An external device connected to the buildings mains supply via a plug point that reduces the mains voltage to...

Page 5: ...Board DuraOp cs Wireless Safety Beams REV LIMITS AUX LOCK 12V TRIG INF GND NO GND COM 12V 24V NC FET Power Input Cau on When ng a Magne c Lock to the door no NOT use the power from the operator as th...

Page 6: ...AYOUT CONTROL BOARD LAYOUT REV LIMITS AUX LOCK 12V TRIG INF GND Inputs Outputs Power Input 12 18V AC or 17 22V DC Solar ve ve Ba ery Cables Motor Wire Red Motor Wire Black Blue 20A Fuse Motor DBUS Inp...

Page 7: ...you to the Programming Menu Pr R c SET p r SET b c SET L E 18 L o SET 1 Ensure the ba ery is connected to the Operator 2 Press the SET bu on to enter the Programming Menu Pr 3 Press the DOWN bu on un...

Page 8: ...5 Press the DOWN bu on un l Lt Light is visible 6 Press and hold the remote bu on that is to be used to turn the operator light on and o Do not use the same bu on that was programmed to trigger the op...

Page 9: ...enu Pr 3 Press the DOWN bu on un l the Remote Menu rc is visible 4 Press the SET bu on to enter the Remote Menu The display will change to LE Learn 5 To program a remote press and hold the remote bu o...

Page 10: ...hts or bypass alarm passives when entering the garage Press the SET bu on to enter the AL menu Press the UP or DOWN bu ons to scroll through the me op ons T0 to T9 Press the SET bu on to select the de...

Page 11: ...re is free movement of the Li ing Assembly on the Drive Channel Li the door s manually to various heights and ensure that the door s do not close under their own weight If they do then it will be nece...

Page 12: ...ng the door will stop brie y and then reopen to the fully open posi on If the door is opening and it is stopped within 30cm of the fully closed posi on it will con nue opening when it receives the nex...

Reviews: