background image

PARTS IDENTIFICATION

6

1

12v Ba ery

2

Power Head

3

Trolley

4

Floa ng Bracket

5

Power Head U-Brackets

6

Li ing Assembly

7

Door Reinforcing Plate:

Single Door - (x2)

Double Door - (x4)

8

Door U-Bracket:

Single Door - (x2)

Double Door - (x4)

9

Cross Tube:

Single Door – 600mm

Double Door - 1000mm

10

Lower Limit Adjus ng Bolt

11

Fasteners

12

Transformer

13

4 Bu on Remote (x2)

14

Manual Release Mechanism

15

Door Li ing Tube

Single Door - (x1)

Double Door - (x2)

16

Drive Channel

17

Drive Channel Foot

18

Channel End Stopper (op onal)

Op onal part.

Not supplied in kit.

18

CONTROL BOARD LAYOUT

CONTROL BOARD LAYOUT

REV

LIMITS

AUX LOCK 12V TRIG INF GND 

Inputs / Outputs

Power Input

12 – 18V AC

or

17 – 22V DC (Solar)

+ve

-ve

Ba ery Cables

Motor Wire

(Red)

Motor Wire

(Black/Blue)

20A Fuse

(Motor)

DBUS

Input

Marker

Input

19

1

LIMITS

:

Connect the 4 pin plug from 

the Drum Mount Operator 

(

this is not used on Sec onal or 

Ver cal Mount Operators

).

2

REV

:

Connect the 3 pin plug from 

the motor to the connector. 

(

this is not used on Drum 

Mount Operators

).

1

2

ADVANCED CONTROLLER PROGRAMMING OPTIONS

1.

External trigger

The LUX operator can be ac vated using other external devices such as Push Bu ons, external Receivers or GSM 

Receivers

LUX DC12

Control Board

External Receiver

REV

LIMITS

AUX LOCK 12V TRIG INF GND 

NO

GND

COM

12V/

24V

External

Push Bu on

Power

Input

Summary of Contents for LUX DC12

Page 1: ...the operator such as a transformer ba ery or beams warranty informa on regarding products may be found in the installa on guide pertaining to each product This warranty explicitly only covers the repa...

Page 2: ...wo of the remote bu ons simultaneously This will reduce the risk of accidentally ac va ng the Lockout func on ES Encoder Stop Fault Obstruc on Cause The operator has stalled This could be as a result...

Page 3: ...ers The advanced engineering and high quality construc on of each DACE product we build is something of which we are proud The LUX DC12 garage operator is packed with features to bring you convenience...

Page 4: ...energy instead of a buildings mains supply for charging the operator s ba ery Transformer An external device connected to the buildings mains supply via a plug point that reduces the mains voltage to...

Page 5: ...Board DuraOp cs Wireless Safety Beams REV LIMITS AUX LOCK 12V TRIG INF GND NO GND COM 12V 24V NC FET Power Input Cau on When ng a Magne c Lock to the door no NOT use the power from the operator as th...

Page 6: ...AYOUT CONTROL BOARD LAYOUT REV LIMITS AUX LOCK 12V TRIG INF GND Inputs Outputs Power Input 12 18V AC or 17 22V DC Solar ve ve Ba ery Cables Motor Wire Red Motor Wire Black Blue 20A Fuse Motor DBUS Inp...

Page 7: ...you to the Programming Menu Pr R c SET p r SET b c SET L E 18 L o SET 1 Ensure the ba ery is connected to the Operator 2 Press the SET bu on to enter the Programming Menu Pr 3 Press the DOWN bu on un...

Page 8: ...5 Press the DOWN bu on un l Lt Light is visible 6 Press and hold the remote bu on that is to be used to turn the operator light on and o Do not use the same bu on that was programmed to trigger the op...

Page 9: ...enu Pr 3 Press the DOWN bu on un l the Remote Menu rc is visible 4 Press the SET bu on to enter the Remote Menu The display will change to LE Learn 5 To program a remote press and hold the remote bu o...

Page 10: ...hts or bypass alarm passives when entering the garage Press the SET bu on to enter the AL menu Press the UP or DOWN bu ons to scroll through the me op ons T0 to T9 Press the SET bu on to select the de...

Page 11: ...re is free movement of the Li ing Assembly on the Drive Channel Li the door s manually to various heights and ensure that the door s do not close under their own weight If they do then it will be nece...

Page 12: ...ng the door will stop brie y and then reopen to the fully open posi on If the door is opening and it is stopped within 30cm of the fully closed posi on it will con nue opening when it receives the nex...

Reviews: