background image

 

 
 
 
 
 
 

 

                                    
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

IT 

SERIE 4GG – 4TW 

Istruzioni d’installazione e uso 

 

 

 

EN 

4GG – 4TW SERIES 

Installation and Operating Instructions 

 

 

FR 

SÉRIE 4GG – 4TW 

Instructions pour l’installation et l’utilisation 

 

  4GG - 4TW 

Summary of Contents for 4GG-4TW Series

Page 1: ...IT SERIE 4GG 4TW Istruzioni d installazione e uso EN 4GG 4TW SERIES Installation and Operating Instructions FR S RIE 4GG 4TW Instructions pour l installation et l utilisation 4GG 4TW...

Page 2: ...result in electric shock WARNING Failure to observe this warning may cause damage to property pump system panel or the environment Read this manual carefully before proceeding 1 Overview page 6 2 Prod...

Page 3: ...a di liquidi corrosivi esplosivi acqua particolarmente sporca o dura possibilit di depositi sulla camicia esterna del motore 3 1 2 Temperatura dell acqua La temperatura minima dell acqua di 0 C La tem...

Page 4: ...artone con dimensioni e forme diverse Immagazzinate il prodotto imballato ad una temperatura ambiente compresa tra 5 e 40 C Gli imballi prevedono il trasporto la movimentazione e l immagazzinamento in...

Page 5: ...co di collegamento riportato sulla camicia esterna del motore e in figura 1 e alla documentazione fornita assieme al quadro elettrico Solo per motori serie 4GG Per la capacit del condensatore fate rif...

Page 6: ...water impurities may deposit on the outer casing 3 1 2 Water temperature Minimum water temperature is 0 C Maximum water temperature is 35 C as long as the flowrate of the water around the motor does...

Page 7: ...le products carefully using suitable lifting equipment Observe accident prevention regulations Do not lift or carry motors by their power cord On receipt of the motor check the box for signs of damage...

Page 8: ...nly for motors 4GG series Refer to the motor rating plate for the capacity of the capacitor Install the electrical panel in a sheltered area Three phase version Connect the electric pump to a supply l...

Page 9: ...t sale ou dure possibilit de d p ts sur la chemise externe du moteur 3 1 2 Temp rature de l eau La temp rature minimum de l eau est de 0 C La temp rature maximum admissible de l eau est de 35 C condit...

Page 10: ...arton de dimensions et de formes diverses Stocker le produit emball une temp rature ambiante comprise en 5 C et 40 C Les emballages pr voient le transport la manutention et le stockage en position hor...

Page 11: ...moteur et dans la figure 1 ainsi qu la documentation fournie avec le coffret lectrique Uniquement pour les moteurs s rie 4GG Pour la capacit du condensateur se r f rer aux donn es figurant sur la plaq...

Page 12: ...3 2 2 413 13 8 5 3 7 6000N 684 26 5 THREE PHASE 0 5 0 37 3 2000N 216 6 0 0 75 0 55 236 6 7 1 0 75 266 8 0 1 5 1 1 286 9 0 2 1 5 3000N 348 11 0 3 2 2 393 13 0 4 3 6000N 544 19 7 5 5 4 614 23 0 7 5 5 5...

Page 13: ...4 63 94 156 250 0 55 0 75 45 67 112 179 267 0 75 1 39 59 98 156 233 1 1 1 5 28 42 69 110 165 273 1 5 2 22 32 54 86 128 213 337 2 2 3 24 41 65 97 161 256 3 7 5 26 42 63 104 166 256 220 230 0 37 0 5 3 4...

Page 14: ...6 25 A max 10 16 25 29 36 51 67 89 V kW Hp Lunghezza massima maximum lenght Longueur maximum mt 220 230 0 37 0 5 1 4 63 94 156 250 0 55 0 75 45 67 112 179 267 0 75 1 39 59 98 156 233 1 1 1 5 28 42 69...

Page 15: ...15...