Screen Adjustment for 120V Screens

If your Tensioned Cosmopolitan Electrol was ordered as a complete unit, the up and down limits were pre-set by Da-Lite. If your screen  
and roller assembly was ordered separately from the case, or if general adjustment is needed, please follow the steps below and  
refer to the 120V Wiring Diagram.

1.   Locate the wall switch and remove the cover plate from the 

wall switch and remove the switch from the junction box.

2.   Locate the two tactile buttons on the back of the switch. 

They are black round buttons on silver plates. See 120V 

Wiring Diagram.

3.   To adjust the down limit switch, press and hold the down 

tactile button until the LED on the back of the switch turns 
solid red. This will put the motor in limit set mode. Turn the 
wall switch over and use the down button on the front of the 
switch. Press and hold the down button until the desired 
down position is reached. If you travel too far down, press 
the up button to move the screen upward. If you press and 
let go of either the up or down buttons, the motor will do a 
small jog in that direction for fine adjustment of the screen. 
Once the desired position is reached, turn the switch over; 
press and hold the down tactile button until the LED on back 
of switch blinks red twice. The down limit is now set.

 

CAUTION: Do not adjust for more drop than what was 
ordered. At least 1–1/2 wraps of fabric must remain on  
the roller. This screen comes standard with 12" black  

at the top. 

 

ATTENTION! N'effectuez pas de réglage pour obtenir un 

déroulement supérieur à celui commandé. Au moins 1 à 

1/2 tour de toile doit être maintenu sur le cylindre. Ce 

écran est doté de série d'une bande noire supérieure de 
30,5 cm (12 po).

 

NOTE:

 If the screen is in limit set mode and no buttons are 

pushed for 20 seconds, the LED on the back of the wall 

switch will turn off, the motor will return to run mode and no 
changes will be saved. If this occurs, return to step 3 for 
down limit adjustment or step 4 for up limit adjustment.

4.   To adjust the up limit switch, press and hold the up tactile 

button until the LED on the back of the switch turns solid 
green. This will put the motor in limit set mode. Turn the wall 
switch over and use the up button on the front of the switch. 
Press and hold the up button until the desired up position is 
reached. If you travel too far up, press the down button to 
move the screen downward. If you press and let go of either 
the up or down buttons, the motor will do a small jog in that 
direction for fine adjustment of the screen. Once the desired 
position is reached, turn the switch over; press and hold the 
up tactile button until the LED on back of switch blinks green 
twice. The up limit is now set.

 

CAUTION: Adjusting the down limit switch for less drop 

by more than 6” can cause the screen surface to lose 
proper tensioning.

 

ATTENTION! Le fait d'ajouter ne déroulez pas trop l'écran 

plus de 15 cm (6po) aux interrupteurs de fin de course 
peut faire perdre la bonne tension à la surface de l'écran.

5.   To test the limit switch settings, press and release the up or 

down buttons on the switch to operate the screen.

6.  Replace the switch and cover plate on the wall.
 

IMPORTANT NOTE: 

The wall switch is REQUIRED to make 

any limit switch adjustments, even if a third party control 
system is used. Therefore, it is advised to wire the switch or 
provide a 3-conductor connection that is accessible.

Low Voltage Connections for 120V Screens with Built-In Low Voltage Control

Control Panel

A control panel may be connected to the splitter board by using 
the dry contact Up, Down and Common connections. The 
control panel must provide a momentary, dry contact closure of 
at least 1/2 second.

1.  Use 3-conductor 20-24 gauge wire to connect the control panel 

to the splitter board.

2.  A momentary closure across the common and up wires will be 

an “up” command.

3.  A momentary closure across the common and down wires will 

be a “down” command.

4.  A momentary closure across the common, up and down wires 

will be a “stop” command.

Summary of Contents for TENSIONED LARGE COSMOPOLITAN ELECTROL

Page 1: ...INSTRUCTION BOOK FOR Tensioned Large Cosmopolitan Electrol ...

Page 2: ...before installing the component 7 Use this projection screen only for its intended use as described in these instructions Do not use attachments not recommended by the manufacturer Save These Instructions Original Instructions Disclaimer Legrand AV and its affiliated corporations and subsidiaries intend to make this manual accurate and complete However Legrand AV makes no claim that the informatio...

Page 3: ... Mount 1 Be sure the ceiling has adequate reinforcement to attach the screen brackets 2 The ceiling brackets are pre attached to the wall mount bracket using 5 16 x 3 4 bolts washers and nuts The brackets can be adjusted within the ranges shown in figure 3 NOTE All four ceiling brackets must be used when mounting to the ceiling or suspending the screen 3 Position the ceiling bracket assembly on th...

Page 4: ...tch To use multiple switches an optional low voltage control must be used This Switch Can Not be used with LVC 120V Wiring Diagram For Standard Wall Switch SPDT Switch with Center Off AC Common AC Hot 120VAC 60HZ Black Yellow Black Red White White Red Up Black Down Junction Box Located In Left Endcap White White Red Black Green Motor NOTE A single switch cannot be used to operate more than one scr...

Page 5: ...ire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is access...

Page 6: ...ing code Blue AC Common Brown AC Hot 230V AC 50Hz Green Yellow Ground Jumper Wire Green Yellow Ground Motor NOTE A single switch cannot be used to operate more than one screen In multiple control installations this switch is replaced by the low voltage control operated from push button stations Contact the factory for further information To Junction Box Mounted In Screen Case In Which Internal Wir...

Page 7: ...le ILT RJ 9 Pin Outs Tab Is Facing Down Ground Common IR or Up 5V Data or Down Red Green White Black UP DN UP 5V COM DN UP STOP DOWN GND 5V 3 POSITION SWITCH RJ9 RJ9 RJ9 Motor Front of Wall Switch Splitter Dry Contacts Back of Wall Switch Green Brown Hot Blue Common NOTE Ground Must be Connected to Building Ground Ground to Case Green Power Input 240VAC 50Hz 240V Wiring Diagram with Optional Built...

Page 8: ...d If this occurs return to step 3 for down limit adjustment or step 4 for up limit adjustment 4 To adjust the up limit switch press and hold the up tactile button until the LED on the back of the switch turns solid green This will put the motor in limit set mode Turn the wall switch over and use the up button on the front of the switch Press and hold the up button until the desired up position is ...

Page 9: ...ATTENTION Le fait d ajouter ne déroulez pas trop l écran plus de 15 cm 6po aux interrupteurs de fin de course peut faire perdre la bonne tension à la surface de l écran 6 When the screen is in the desired up position slide the 3 position switch to the off center position The up limit switch is now set 7 To test limit switch setting make sure the 3 position switch is in the off center position Pres...

Page 10: ...the down or up position Check for continuity Cut off old splice and reconnect Defective motor limit switch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Capacitor burned out Replace motor assembly Incorrect stopping position in downward direction Lost roller wrap See instructions below Down limit switch out of adjustment Contact Da Lite at 800 622 3737 or 574 267 8101 Incorre...

Page 11: ...11 ...

Page 12: ... BY APPLICABLE LAW NO LIABILITY IS ASSUMED FOR EXPENSES OR DAMAGES RESULTING FROM INTERRUPTION IN OPERATION OF EQUIPMENT OR FOR INCIDENTAL DIRECT OR CONSEQUENTIAL DAMAGES OF ANY NATURE In the event that there is a defect in materials or workmanship of a Da Lite product you may contact our Customer Care Specialists at 3100 North Detroit Street Warsaw IN 46582 574 267 8101 800 622 3737 IMPORTANT THI...

Reviews: