background image

9

1. 

Remove the cover plate from the 3-button wall switch and 
remove the switch from the junction box.

2.  Locate small 3-position switch on back of wall switch. See 

Figure 5 for 120V screens or Figure 8 for 220/240V screens.

3.  To adjust the down limit switch, slide the 3-position switch to 

the down position. Press and hold the down button to run 
the screen down to the desired stop position. Release the 
button to stop the screen. DO NOT PUSH THE STOP 
BUTTON.

 

CAUTION: Do not adjust for more drop than what was 
ordered. At least 1–1/2 wraps of fabric must remain on 
the roller. This screen comes standard with 12" black at 
the top. See the specification data sheet for details.

 

ATTENTION! N'effectuez pas de réglage pour obtenir un 

déroulement supérieur à celui commandé. Au moins 1 à 

1/2 tour de toile doit être maintenu sur le cylindre. Ce 

écran est doté de série d'une bande noire supérieure de 
30,5 cm (12 po).

4.  When the screen is in the desired down position, slide the 

3-position switch to the off (center) position. The down limit 

switch is now set.

5.  To adjust the up limit switch, slide the 3-position switch to 

the up position. Press and hold the up button to run the 
screen up to the desired stop position. Release the button to 
stop the screen. DO NOT PUSH THE STOP BUTTON.

 

CAUTION: Adjusting the down limit switch for less drop 

by more than 6” can cause the screen surface to lose 
proper tensioning.

 

ATTENTION! Le fait d'ajouter ne déroulez pas trop l'écran 

plus de 15 cm (6po) aux interrupteurs de fin de course 
peut faire perdre la bonne tension à la surface de l'écran.

6.  When the screen is in the desired up position, slide the 

3-position switch to the off (center) position. The up limit 

switch is now set.

7. 

To test limit switch setting, make sure the 3-position switch is 
in the off (center) position. Press and release the up or down 
button on the wall switch to operate the screen.

8.  Replace switch and cover plate on the wall.
 

NOTE:

 If stop button is pressed, the wall switch will reverse 

direction. To correct this, press the stop button again. This 

will reset the switch. You will have to re-set both the up and 
the down limit settings.

 IMPORTANT 

NOTE: 

The wall switch is REQUIRED to make 

any limit switch adjustments, EVEN if a third party control 
system is used. Therefore, it is advised to wire the switch or 
provide a 4-conductor connection that is accessible.

Screen Adjustment for 220V/240V Screens

Low Voltage Connections for 220V/240V Screens with Built-In Low Voltage Control

Control Panel

A control panel may be connected to the integrated LVC by 
using the wall switch wire lead. The control panel must provide a 
momentary, dry contact closure of at least 1/2 second.

1.  Use 3-conductor 20-24 gauge wire to connect the control panel 

to the wall switch lead.

2.  A momentary closure across the white and red wires will be an 

“up” command.

3.  A momentary closure across the white and black wires will be a 

“down” command.

4.  A momentary closure across the white, red and black wires will 

be a “stop” command.

Summary of Contents for TENSIONED LARGE COSMOPOLITAN ELECTROL

Page 1: ...INSTRUCTION BOOK FOR Tensioned Large Cosmopolitan Electrol ...

Page 2: ...before installing the component 7 Use this projection screen only for its intended use as described in these instructions Do not use attachments not recommended by the manufacturer Save These Instructions Original Instructions Disclaimer Legrand AV and its affiliated corporations and subsidiaries intend to make this manual accurate and complete However Legrand AV makes no claim that the informatio...

Page 3: ... Mount 1 Be sure the ceiling has adequate reinforcement to attach the screen brackets 2 The ceiling brackets are pre attached to the wall mount bracket using 5 16 x 3 4 bolts washers and nuts The brackets can be adjusted within the ranges shown in figure 3 NOTE All four ceiling brackets must be used when mounting to the ceiling or suspending the screen 3 Position the ceiling bracket assembly on th...

Page 4: ...tch To use multiple switches an optional low voltage control must be used This Switch Can Not be used with LVC 120V Wiring Diagram For Standard Wall Switch SPDT Switch with Center Off AC Common AC Hot 120VAC 60HZ Black Yellow Black Red White White Red Up Black Down Junction Box Located In Left Endcap White White Red Black Green Motor NOTE A single switch cannot be used to operate more than one scr...

Page 5: ...ire can be used in place of the supplied RJ 14 cable to connect the wall switch Connect the BUS terminals on the wall switch to the corresponding BUS terminals on the splitter board IMPORTANT NOTE The wall switch is REQUIRED to make any limit switch adjustments EVEN if a third party control system is used Therefore it is advised to wire the switch or provide a 3 conductor connection that is access...

Page 6: ...ing code Blue AC Common Brown AC Hot 230V AC 50Hz Green Yellow Ground Jumper Wire Green Yellow Ground Motor NOTE A single switch cannot be used to operate more than one screen In multiple control installations this switch is replaced by the low voltage control operated from push button stations Contact the factory for further information To Junction Box Mounted In Screen Case In Which Internal Wir...

Page 7: ...le ILT RJ 9 Pin Outs Tab Is Facing Down Ground Common IR or Up 5V Data or Down Red Green White Black UP DN UP 5V COM DN UP STOP DOWN GND 5V 3 POSITION SWITCH RJ9 RJ9 RJ9 Motor Front of Wall Switch Splitter Dry Contacts Back of Wall Switch Green Brown Hot Blue Common NOTE Ground Must be Connected to Building Ground Ground to Case Green Power Input 240VAC 50Hz 240V Wiring Diagram with Optional Built...

Page 8: ...d If this occurs return to step 3 for down limit adjustment or step 4 for up limit adjustment 4 To adjust the up limit switch press and hold the up tactile button until the LED on the back of the switch turns solid green This will put the motor in limit set mode Turn the wall switch over and use the up button on the front of the switch Press and hold the up button until the desired up position is ...

Page 9: ...ATTENTION Le fait d ajouter ne déroulez pas trop l écran plus de 15 cm 6po aux interrupteurs de fin de course peut faire perdre la bonne tension à la surface de l écran 6 When the screen is in the desired up position slide the 3 position switch to the off center position The up limit switch is now set 7 To test limit switch setting make sure the 3 position switch is in the off center position Pres...

Page 10: ...the down or up position Check for continuity Cut off old splice and reconnect Defective motor limit switch or capacitor Replace motor assembly NOTE Motor is a sealed assembly Capacitor burned out Replace motor assembly Incorrect stopping position in downward direction Lost roller wrap See instructions below Down limit switch out of adjustment Contact Da Lite at 800 622 3737 or 574 267 8101 Incorre...

Page 11: ...11 ...

Page 12: ... BY APPLICABLE LAW NO LIABILITY IS ASSUMED FOR EXPENSES OR DAMAGES RESULTING FROM INTERRUPTION IN OPERATION OF EQUIPMENT OR FOR INCIDENTAL DIRECT OR CONSEQUENTIAL DAMAGES OF ANY NATURE In the event that there is a defect in materials or workmanship of a Da Lite product you may contact our Customer Care Specialists at 3100 North Detroit Street Warsaw IN 46582 574 267 8101 800 622 3737 IMPORTANT THI...

Reviews: