Document Number:
V024944_03_Mini_Rad-DX_Manual
Date:
1/19/2015
Page:
3 of 28
D-tect Systems
11814 South Election Rd. Suite 200, Draper, UT 84020
(801) 495-2310
FAX (801) 495-2255
1
Introduction
The MiniRad-DX is a handheld security and inspection device that detects emissions from
radioactive material. The MiniRad-DX system can operate as a stand-alone detector or as the
roving detection part of a larger MiniRad-DX and Rad-DX network for monitoring a building or
facility.
The MiniRad-DX is not intended to be used as a personal dosimeter.
The MiniRad-DX is not certified for explosive atmospheres.
1.1 Key Features
Device Highlights
High sensitivity detector (CsI scintillator with PMT)
Operator selectable alarm levels (password controlled)
Two bright, high-resolution display screens
Real-time dose rate graph
Units displayed in rems per hour, Sieverts per hour, or counts per second
130 hours between recharge (depending on options selected)
Integrated GPS for complete logging of dose rate, location, and time
Vibrate or audio alarm
Designed to be ANSI N42.32, N42.33 and N42.42 compliant
D-tect SensorNet (Mesh) Network
Integrated mesh radio
2.4 GHz, 15 selectable channels
Network range between devices is 1000m RF line-of-sight
Up to 50 devices per network
Easy to set-up and modify network
Interoperable with DX Link mesh relays for extended wireless range
Communication and Security
Mini USB interface
128 bit AES encryption (D-tect SensorNet)
With Network Integration
Real-time control and monitoring of an entire network via smartphone, PC, or tablet
Network can include Rad-DX area monitors and Rad-DXG portal monitors