Warranty for D-tect System Products 

 

1. What this Warranty Covers and for How Long 

 
D-tect  Systems  (“D-tect  Systems”)  warrants  this  device  (the  "Product")  against  defects  in  materials  and 
workmanship under normal use for a period of two years from the date of purchase. This warranty extends to the 
first  end-user  purchaser  only,  and  is  not  transferable.  This  warranty  does  not  extend  to  other  ancillary  and/or 
consumable products including but  not limited to batteries, calibration sources, straps, and shipping cases. D-tect 
Systems, at its option, will at no charge either repair, replace or refund the purchase price of any Products that do 
not  conform  with  this  warranty.  Repair  may  include  the  replacement  of  parts  with  functionally  equivalent 
reconditioned  or  new  parts.  Replacement  may  include  providing  a  functionally  equivalent  Certified 
Reconditioned/Pre-owned  or  a  new  Product.  Products  that  have  been  repaired  or  replaced  are  warranted  for  the 
balance  of  the  original  warranty  period  or  for  90  days  from  the  date  that  the  repaired  or  replaced  Product  is 
received by you, whichever is longer. All Products for which replacements have been provided will become D-tect 
Systems property. 
 

2. Other Warranty Conditions 

 
This  warranty  is  D-tect  Systems’  complete  warranty  for  the  Product.  D-tect  Systems  assumes  no  obligation  or 
liability for changes to this warranty unless made in writing and signed by an officer of D-tect Systems. 
 
If D-tect Systems agrees to perform services requested and approved by the customer that are not included in either 
the Limited or Extended Warranty, these services will be billed to the customer at D-tect Systems’ standard prices 
and terms.  
 
D-tect  Systems  does  not  warrant  any  installation,  maintenance,  or  service  that  it  did  not  perform.  SERVICE 
WORK PERFORMED BY SERVICE CENTERS NOT AUTHORIZED BY D-TECT SYSTEMS TO PERFORM 
SUCH WORK WILL VOID THIS WARRANTY. 
 

3. What This Warranty Does Not Cover 

 
a.

 

Defects or damage resulting from: collision of the Product with hard surfaces, contact with water, rain or 

extreme  humidity,  contact  with  sand,  dirt  or  the  like,  contact  with  extreme  heat  or  cold,  spills  of  food  or  liquid, 
improper testing, operation, maintenance, installation, adjustment; or any alteration or modification of any kind. 
b.

 

Normal “wear and tear” of the Product such as scratches, scuffs, and marks on the LCD, case and other 

external features. 
c.

 

Cracked or broken displays, buttons, or damage to other externally exposed parts caused by abnormal use 

and/or abuse of the Product. 
d.

 

Products  disassembled  or  repaired  in  such  a  manner  as  to  adversely  affect  performance  or  prevent 

adequate inspection and testing to verify any warranty claim. 
e.

 

Products on which serial numbers or date tags have been removed, altered or obliterated. 

 

4. How to Get Warranty Service 

 
To get warranty service, please contact your distributor or D-tect Systems at 

www.dtectsystems.com

 . 

 
You will receive directions on how to mail the Product to D-tect Systems. All Products shipped to D-tect Systems 
must be shipped with freight and insurance prepaid. Along with the Product you must include a receipt, bill of sale, 
or  some  other  comparable  proof  of  purchase,  a  written  description  of  the  problem  and,  most  importantly,  your 
address  and  telephone  number.  If  additional  information  is  needed,  please  contact  D-tect  Systems  at  the  web 
address indicated above.  

Summary of Contents for MiniRad-DX

Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS FOR THE RADIATION DETECTION SYSTEM D tect Systems Group Visionary Products Inc 11814 South Election Road Suite 200 Draper UT 84020 www dtectsystems com...

Page 2: ...ttery Life 6 6 Recharging the MiniRad DX 6 7 Startup 7 8 Operation 8 8 1 Communication Icons 9 8 2 Graph Screen 10 8 3 Main Menu Screen 11 8 4 Device Menu 12 8 5 GPS Menu 13 8 6 Alerts Menu 14 8 6 1 A...

Page 3: ...levels password controlled Two bright high resolution display screens Real time dose rate graph Units displayed in rems per hour Sieverts per hour or counts per second 130 hours between recharge depe...

Page 4: ...user interaction required 2 Getting Started Guides Additional documentation such as Getting Started Installation and Quick Start Guides is available to help you setup your MiniRad DX network of detect...

Page 5: ...11814 South Election Rd Suite 200 Draper UT 84020 801 495 2310 FAX 801 495 2255 3 Box Contents Figure 1 MiniRad DX Handheld Radiation Detector Other hardware components packaged with each MiniRad DX...

Page 6: ...installed at your facility Using the DX Dashboard you can access your Rad DX network using any web enabled device smartphones tablets PCs The DX Dashboard Setup Tool is needed to initially configure...

Page 7: ...Suite 200 Draper UT 84020 801 495 2310 FAX 801 495 2255 7 Startup To power on your MiniRad DX press and hold the power button for about 1 second The first screen to appear is the Home screen Use the...

Page 8: ...p screens Options for the MiniRad DX such as screen brightness screen sleep timers and radiation units can be set up using the following process 1 The Home Screen will appear on the LCD screen after p...

Page 9: ...iniRad DX is plugged into a USB port This indicates that the device is charging When 20 or less of the battery is remaining the icon will change to red indicating a low battery Mesh Network The mesh n...

Page 10: ...ays the detected radiation levels in a convenient graph timeline of 90 seconds The numerical dose rate and the graph window display a dose rate with a 15 second average background filter The backgroun...

Page 11: ...reen can be accessed by pressing the upper right navigation button on the keypad The available options inside the menu are Device GPS Alerts and Display Use the directional keys on the keypad to open...

Page 12: ...4020 801 495 2310 FAX 801 495 2255 8 4 Device Menu The device menu displays device specific information including device name firmware version battery state mesh signal strength and current mesh chann...

Page 13: ...GPS Menu The GPS feature can be toggled on and off in this menu The GPS feature is for outdoor use or use when the device is in view of at least three satellites The time it takes for the device to re...

Page 14: ...rm level and dose rate the top screen will display either the dose rate or a 0 9 alarm level depending on configuration and the sound and vibration alarms will also activate The sound and vibration fe...

Page 15: ...formation The Mini Rad DX measures accumulative dose levels for each device and displays it on the home screen Figure 10 Home Screen with Accumulative Dose In order to view the settings which have bee...

Page 16: ...Dose Alarm can be done by pressing the Reset Dose button on the device in the Alerts Alarm Thresholds menu 8 6 2 Alarm Options The different levels of alarm thresholds are reported in the Alerts Menu...

Page 17: ...onal 1 9 Top Display The top screen can be configured to display 1 9 alarm levels similar to the original Mini Rad D radiation detector All 9 alarm levels can be modified by the user with the DX View...

Page 18: ...settings will affect the time that the MiniRad DX can operate between charges 8 7 1 Date Time Settings The default time setting for the MiniRad DX is GMT Greenwich Mean Time Use the DX View software t...

Page 19: ...o function longer between charges For example say that a security guard is carrying a MiniRad DX with them on their rounds through the building Typical use would have them wearing the device on their...

Page 20: ...Center of Detector The target symbol on the back label of the MiniRad DX represents the most sensitive portion of the detector which is also referred to as the effective center of detection Always po...

Page 21: ...tive cover and has two primary functions charging the internal battery and communicating directly to your PC running the DX View software Connect the USB cable to the MiniRad DX and the USB power adap...

Page 22: ...the Rad DX family of devices The D tect Cloud Network is an easy method to control and monitor a network of detectors in the Rad DX family It also allows the detectors to be monitored via smartphone...

Page 23: ...4020 801 495 2310 FAX 801 495 2255 Figure 21 DX Assistant Network A Rad DX network can include Rad DX area monitors Rad DXG gateway monitors MiniRad DX handheld units and DX Link repeater gateway devi...

Page 24: ...ick display for detection status Main Display o Type Transflective TFT LCD o Resolution 320 x 240 o Color Depth 18 bits providing up to 262 144 color rendering Top Display o Type Organic LED o Resolut...

Page 25: ...par la partie responsible de la conformit ont pu vider I autorit de I utilisateur pour actioner cet equipment This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de l...

Page 26: ...th IC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator and your body Note Importante...

Page 27: ...proved by the customer that are not included in either the Limited or Extended Warranty these services will be billed to the customer at D tect Systems standard prices and terms D tect Systems does no...

Page 28: ...ecome or in D tect System s opinion be likely to become the subject of a claim of infringement of a United States patent that you will permit D tect Systems at its option and expense either to procure...

Reviews: