xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
968
Command: config time_zone op hour 2 min 30
Success.
DGS-3420-28SC:admin#
26-8
config dst
Description
This command is used to change Daylight Saving Time settings.
Format
config dst [disable | repeating {s_week <start_week 1-4,last> | s_day <start_day sun-sat> |
s_mth <start_mth 1-12> | s_time <start_time hh:mm> | e_week <end_week 1-4, last> | e_day
<end_day sun-sat> | e_mth <end_mth 1-12> | e_time <end_time hh:mm> | offset [30 | 60 | 90 |
120]} (9) | annual {s_date <start_date 1-31> | s_mth <start_mth 1-12> | s_time <start_time
hh:mm> | e_date <end_date 1-31> | e_mth <end_mth 1-12> | e_time <end_time hh:mm> | offset
[30 | 60 | 90 | 120]} (7) ]
Parameters
disable
- Disable the DST of the switch.
repeating
- Set the DST to repeating mode.
s_week
- Configure the start week number of DST.
<start_week 1-4,last>
- Configure the start week number of DST. The values are 1 to 4.
s_day
- Configure the start day number of DST.
<start_day sun-sat>
- Configure the start day number of DST. The values are sun, mon, tue,
wed, thu, fri and sat.
s_mth
- Configure the start month number of DST.
<start_mth 1-12>
- Configure the start month number of DST. The values are 1 to 12.
s_time
- Configure the start time of DST.
<start_time hh:mm>
- Configure the start time in hh:mm of DST.
e_week
- Configure the end week number of DST.
<end_week 1-4,last>
- Configure the end week number of DST. The values are 1 to 4.
e_day
- Configure the end day number of DST.
<end_day sun-sat>
- Configure the end day number of DST. The values are sun, mon, tue, wed,
thu, fri and sat.
e_mth
- (Optional) Configure the end month number of DST.
<end_mth 1-12>
- Configure the end month number of DST. The values are 1 to 12.
e_time
- Configure the end time of DST.
<end_time hh:mm>
- Configure the end time in hh:mm of DST.
offset
- Specify the number of minutes to add or to subtract during summertime. The range of offsets
are 30, 60, 90, and 120. The default value is 60.
30
- Specify 30 minutes to add or to subtract during summertime.
60
- Specify 60 minutes to add or to subtract during summertime.
90
- Specify 90 minutes to add or to subtract during summertime.
120
- Specify 120 minutes to add or to subtract during summertime.
annual
- Set the DST to annual mode.
s_date
- Configure the start date number of DST.
Summary of Contents for xStack DGS-3420 Series
Page 1: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide I ...
Page 188: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 183 ...
Page 713: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 708 ...
Page 902: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 897 ...