xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
721
Format
config syslog host [<index> | all] {severity [emergency | alert | critical | error | warning | notice |
informational | debug | <level 0-7>] | facility [local0 | local1 | local2 | local3 | local4 | local5 |
local6 | local7] | udp_port <udp_port_number> | ipaddress[ <ipaddr> | <ipv6addr>] | state
[enable | disable]} (1)
Parameters
<index>
- Specify the host index.
all
- Specify all hosts.
severity
- (Optional) Specify the severity level supported: emergency, alert, critical, error, warning,
notice, informational, or debug.
emergency
- Specify emergency messages.
alert
- Specify alert messages.
critical
- Specify critical messages.
error
- Specify error messages.
warning
- Specify warning messages.
notice
- Specify notice messages.
informational
- Specify informational messages.
debug
- Specify debug messages.
<level 0-7>
- Specify a level between 0 and 7.
facility
- Some of the operating system daemons and processes have been assigned facility values.
Processes and daemons that have not been explicitly assigned a facility may use any of the"local
use" facilities or they may use the "user-level" facility. Those facilities that have been designated
are shown in the following:
local0
- User-defined facility.
local1
- User-defined facility.
local2
- User-defined facility.
local3
- User-defined facility.
local4
- User-defined facility.
local5
- User-defined facility.
local6
- User-defined facility.
local7
- User-defined facility.
udp_port
- Specify the UDP port number.
<udp_port_number>
- Specify the UDP port number.
ipaddress
- Specify the IPv4 address or IPv6 address of the host.
<ipaddr>
- Specify the IPv4 address of the host.
<ipv6addr>
- Specify the IPv6 address of the host.
state
- The syslog protocol has been used for the transmission of event notification messages across
networks to host. This option enables or disables the host to receive such messages.
enable
- Enable the host to receive messages.
disable
- Disable the host to receive messages.
Restrictions
Only Administrator and Operator-level users can issue this command.
Example
To configure the syslog host configuration:
DGS-3420-28SC:admin# config syslog host all severity informational facility local0
Summary of Contents for xStack DGS-3420 Series
Page 1: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide I ...
Page 188: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 183 ...
Page 713: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 708 ...
Page 902: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 897 ...