Command: config syslog host all severity informational facility local0
Success.
DGS-3420-28SC:admin#
63-16
create syslog host
Description
This command is used to create a new syslog host.
Format
create syslog host <index 1-4> ipaddress [<ipaddr> | <ipv6addr>] {severity [emergency | alert |
critical | error | warning | notice | informational | debug | <level 0-7>] | facility [local0 | local1 |
local2 | local3 | local4 | local5 | local6 | local7] | udp_port <udp_port_number> | state [enable |
disable]}
Parameters
<index 1-4>
- Specify the host index.
ipaddress
- Specify the IPv4 address or IPv6 address of the host.
<ipaddr>
- Specify the IPv4 address of the host.
<ipv6addr>
- Specify the IPv6 address of the host.
severity
- (Optional) Specify the severity level supported: emergency, alert, critical, error,
warning, notice, informational, or debug.
emergency
- Specify emergency messages.
alert
- Specify alert messages.
critical
- Specify critical messages.
error
- Specify error messages.
warning
- Specify warning messages.
notice
- Specify notice messages.
informational
- Specify informational messages.
debug
- Specify debug messages.
<level 0-7>
- Specify a level between 0 and 7.
facility
- Some of the operating system daemons and processes have been assigned facility
values. Processes and daemons that have not been explicitly assigned a facility may use any
of the"local use" facilities or they may use the "user-level" facility. Those facilities that have
been designated are shown in the following:
local0
- User-defined facility.
local1
- User-defined facility.
local2
- User-defined facility.
local3
- User-defined facility.
local4
- User-defined facility.
local5
- User-defined facility.
local6
- User-defined facility.
local7
- User-defined facility.
udp_port
- Specify the UDP port number.
<udp_port_number>
- Specify the UDP port number.
state
- The syslog protocol has been used for the transmission of event notification messages
across networks to host. This option enables or disables the host to receive such messages.
Summary of Contents for xStack DGS-3420 Series
Page 1: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide I ...
Page 188: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 183 ...
Page 713: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 708 ...
Page 902: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 897 ...