![D-Link xStack DGS-3420 Series Reference Manual Download Page 444](http://html.mh-extra.com/html/d-link/xstack-dgs-3420-series/xstack-dgs-3420-series_reference-manual_78239444.webp)
xStack® DGS-3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide
439
Example
To configure the router port of IGMP proxy’s upstream interface:
DGS-3420-28SC:admin#config igmp_proxy upstream_if vlan default router_ports add 3
Command: config igmp_proxy upstream_if vlan default router_ports add 3
Success.
DGS-3420-28SC:admin#
38-5
show igmp_proxy
Description
This command displays IGMP proxy configuration information or group information on the switch. The
display status item means group entry is determined by whether or not the chip is inserted.
Format
show igmp_proxy {group}
Parameters
group
- (Optional) Specify the group information.
Note:
If the group is not specified, the IGMP proxy configuration will be displayed.
Restrictions
None.
Example
To display IGMP proxy information:
DGS-3420-28SC:admin#show igmp_proxy
Command: show igmp_proxy
IGMP Proxy Global State : Enabled
Upstream Interface
VLAN ID : 1
Dynamic Router Ports : 1-4
Static Router Ports : 5-6
Unsolicited Report Interval : 10
Source IP Address : 0.0.0.0
Summary of Contents for xStack DGS-3420 Series
Page 1: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide I ...
Page 188: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 183 ...
Page 713: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 708 ...
Page 902: ...xStack DGS 3420 Series Layer 2 Managed Stackable Gigabit Switch CLI Reference Guide 897 ...