DGS-3200 Series Layer 2 Gigabit Ethernet Managed Switch
162
Figure 10- 17. Add Access Rule window for IPv6
To set the Access Rule for IPv6, adjust the following parameters and click
Apply
.
Parameter Description
Access ID (1-200)
Type in a unique identifier number for this access. This value can be set from
1
to
200
.
Auto Assign – Ticking this check box will instruct the Switch to automatically assign an Access ID
for the rule being created.
Action
Select
Permit
to specify that the packets that match the access profile are forwarded by the
Switch, according to any additional rule added (see below).
Select
Deny
to specify that packets that match the access profile are not forwarded by the Switch
and will be filtered.
Select
Mirror
to specify that packets that match the access profile are mirrored to a port defined
in the config mirror port command. Port Mirroring must be enabled and a target port must be set.
Priority (0-7)
Tick the corresponding check box to re-write the 802.1p default priority of a packet to the value
entered in the Priority field, which meets the criteria specified previously in this command, before
forwarding it on to the specified CoS queue. Otherwise, a packet will have its incoming 802.1p
user priority re-written to its original value before being forwarded by the Switch.
For more information on priority queues, CoS queues and mapping for 802.1p, see the QoS
section of this manual.
Flow Label
Configuring this field, in hex form, will instruct the Switch to examine the flow label field of the
IPv6 header. This flow label field is used by a source to label sequences of packets such as non-
default quality of service or real time service packets.
Rx Rate (1-
156249)
Use this to limit Rx bandwidth for the profile being configured. This rate is implemented using the
following equation: 1 value = 64kbit/sec. (ex. If the user selects an Rx rate of
10
then the ingress
rate is 640kbit/sec.) The user many select a value between
1
and
156249
or tick the No Limit
check box. The default setting is No Limit.
Time Range
Name
Tick the check box and enter the name of the Time Range settings that has been previously
configured in the
Time Range
Settings
window. This will set specific times when this access rule
will be implemented on the Switch.
Ports
When a range of ports is to be configured, the Auto Assign check box MUST be ticked in the
Access ID field of this window. If not, the user will be presented with an error message and the