DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
425
Global Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
Only SFP/SFP+/QSFP+ port interfaces with optical modules, with transceiver monitoring capability, are
valid for this configuration.
This command configures the RX power thresholds on the specified port. This value will be stored both in
the system and in the SFP/SFP+/QSFP+ transceivers and be converted to the 16-bit format and then
written into the SFP/SFP+/QSFP+
module.
If the SFP/SFP+/QSFP+ module configured does not support the threshold change, the user-configured
threshold is just stored in the system and the displayed value will be the user-configured threshold. If
there is no user-configured threshold, the displayed value will always reflect the factory preset value
defined by the vendor.
The
no
form of this command has the effect to clear the configured threshold stored in system. It does not
change the threshold stored in the SFP/SFP+/QSFP+ transceivers. Use
no
form of the command to
prevent threshold values in newly inserted SFP/SFP+/QSFP+ transceivers from being altered.
Example
This example shows how to configure the RX power low warning threshold as 0.135 mW on interface
Ethernet 1/0/1.
Switch# configure terminal
Switch(config)# transceiver-monitoring rx-power ethernet 1/0/1 low warning mwatt 0.135
Switch(config)#
29-7 transceiver-monitoring temperature
This command is used to configure the temperature thresholds for the specified port. Use the
no
form of
the command to remove the configuration.
transceiver-monitoring temperature INTERFACE-ID {high | low} {alarm | warning} VALUE
no transceiver-monitoring temperature INTERFACE-ID {high | low} {alarm | warning}
Parameters
INTERFACE ID
Specifies the interface to modify.
high
Specifies that when the operating parameter rises above this high
threshold value, it indicates an abnormal status.
low
Specifies that when the operating parameter falls below this low
threshold value, it indicates an abnormal status.
alarm
Specifies to configure the high and low threshold value condition.
warning
Specifies to configure the high and low warning threshold conditions.
VALUE
Specifies the threshold value. This value must be between -128 and
127.996 °C.
Default
None.
Command Mode
Global Configuration Mode.
Summary of Contents for DXS-3600 Series
Page 1: ......
Page 423: ...DXS 3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide 418 ...
Page 548: ...DXS 3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide 543 ...
Page 673: ...DXS 3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide 668 ...
Page 712: ...DXS 3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide 707 Switch ...
Page 845: ...DXS 3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide 840 ...