DWS-3160 Series Gigabit Ethernet Unified Switch CLI Reference Guide
259
DWS-3160-24PC:admin#debug show error_reboot state
Command: debug show error_reboot state
Error Reboot: Enabled
DWS-3160-24PC:admin#
22-8
debug show status
Description
This command is used to display the debug handler’s state and to specify the module’s debug
status. If the input module list is empty, the states of all the registered modules, that support the
debug module, will be displayed.
Format
debug show status {module <module_list>}
Parameters
module
– (Optional) Specifies the module list.
<module_list>
- Enter the module list here.
Restrictions
Only Administrators can issue this command.
Example
To display the specified module’s debug state:
DWS-3160-24PC:admin#debug show status module MSTP
Command: debug show status module MSTP
Debug Global State : Enabled
MSTP : Disabled
DWS-3160-24PC:admin#
To display the debug state: