DGS-8000 Series Hardware Installation Guide Chapter 3 Switch Installation
47
(1) Insert the air filter along the guide rail and tighten the captive screws on the air filter.
(2) Install the plastic dust cap before the air filter by pressing firmly the two buttons of the
plastic dust cap on the both sides.
The simple steps for removing the air filters of the host management module and service
module on the DGS-8010 are as follows:
(1) Press the buttons of the plastic dust cap to the bottom and remove the plastic dust cap.
(2) Loosen the captive screws on the air filter.
(3) Take out the air filter.
Figure 3-3 Installation location for the air filters of the host management module and
service module on the DGS-8010
①
Plastic dust cap before the air filter installation location
Buttons on the plastic
②
dust cap
Note
The dust in the air may block the air outlet of an air filter after an air filter is
used for a long time, thus affecting system ventilation and heat dissipation. It
is recommended to clear it once per three months.
Summary of Contents for dgs-8000 SERIES
Page 1: ...DGS 8000 Hardware Installation Guide ...
Page 97: ......