Appendix C – Module Specs and Cable Lengths
Page | 33
A
PPENDIX
C
–
M
ODULE
S
PECS AND
C
ABLE
L
ENGTHS
Use the following table to as a guide for the module specs and maximum cable lengths.
Standard
Media Type
Maximum Distance
Mini-GBIC
1000BASE-LX, Single-mode fiber module
1000BASE-SX, Multi-mode fiber module
1000BASE-LH, Single-mode fiber module
1000BASE-ZX, Single-mode fiber module
10km
550m / 2km
50km
80km
1000BASE-T
Category 5e UTP Cable
100m
100BASE-TX
Category 5 UTP Cable (100 Mbps)
100m
10BASE-T
Category 3, 4 or 5 UTP Cable (10 Mbps)
100m
DEM-310GT
1000Base-LX, Single-mode
10km
DEM-311GT
1000ase-SX, Multi-mode
500m
DEM-312GT2
1000Base-SX, Multi-mode
2km
DEM-314GT
1000BASE-LH, Single-mode
50km
DEM-315GT
1000BASE-ZX, Single-mode
80km
DEM-210
100BASE-FX, Single-mode
15km
DEM-211
100BASE-FX, Multi-mode
2km
DEM-220T
100BASE-BX, Single-mode
Up to 20km
DEM-220R
100BASE-BX, Single-mode
Up to 20km
DEM-330T
TX-1550/RX-1310nm, Single-mode
Up to 10km
DEM-330R
TX-1310/RX-1550 nm, Single-mode
Up to 10km
DEM-331T
TX-1550/RX-1310 nm, Single-Mode
Up to 40km
DEM-331R
TX-1310/RX-1550 nm, Single-Mode
Up to 40km
Network pluggable optical modules meet the following regulatory requirements:
•
Class 1 Laser Product
•
EN60825-1+A2:2001 or later, European laser standard
•
FCC 21 CFR Chapter 1, Subchapter J in accordance with FDA & CDRH requirements