background image

appliances are disposed of in landfills or dumps, hazardous substances

can leak into the groundwater and get into the food chain, damaging

your health and well-being.

When replacing old appliances with new once, the retailer is legally

obligated to take back your old appliance for disposal at least for free

of charge.

9

Summary of Contents for DCH-112

Page 1: ...s The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Add to Remove from Z WaveTM Network There are two tamper keys in the device one is in the back side another is in the front side Both of them can add remove reset or association...

Page 2: ...ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeout after 30 seconds You can press the tamper key 3 times to abort the NWI mode Z WaveTM Notification After the device adding to the network it will wake up once per day in ...

Page 3: ...ery 6 hours report once in default It could be changed by setting the configuration NO 10 Low battery report When the battery level is too low every 30 minutes will report once Door window state report Every 6 hours report once in default It could be changed by setting the configuration NO 11 Illumination level report Every 6 hours report once in default It could be changed by setting the configur...

Page 4: ...also will light ON one second When the event triggered the device will report the messages to the nodes in the group 1 The messages also include the battery level the temperature and the illumination level The user can switch the report by setting the configuration NO 5 bit4 illumination and bit5 temperature and the configuration NO 7 bit6 battery When the event triggered if the environment lumina...

Page 5: ...he device trig please associate with the device into the second group 3 In the accessory pack There are two type of double coated tape one is thicker hereinafter referred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let ...

Page 6: ...report after event triggered 1 Disable 0 Enable 0 Bit5 Disable the temperature report after event triggered 1 Disable 0 Enable NO Name Def Vali d A B C Description 0 Bit6 Reserve 0 Bit7 Disable the back key release into test mode 1 Disable 0 Enable 7 Customer Function 4 All Customer function switch using bit control Caution The value is unsigned byte the range is from 0x00 0xFF 0 Bit0 Reserve 0 Bi...

Page 7: ...Setting to 0 means turn off all auto report function Caution2 The value is unsigned byte the range is from 0x00 0xFF Z Wave Supported Command Class COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_SE...

Page 8: ...wever there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between t...

Page 9: ...s substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge 9 ...

Reviews: