NO
.
Name
Def.
Vali
d
A B C
Description
2 Basic Set
Level
0xFF
All
Setting the BASIC command value to
turn on the light. The 0xFF(-1) means
turn on the light. For dimmer
equipment 1 to 100 means the light
strength.
0 means turn off the light.
Caution
: The value is unsigned byte,
the range is from 0x00 ~ 0xFF.
5
(*)
Operation
Mode
0
All
Operation mode. Using bit to control.
Caution
: The value is unsigned byte,
the range is from 0x00 ~ 0xFF.
0
Bit0
: Reserve.
0
Bit1
: 1 means test mode,
0 means normal mode.
Notice:
This bit only effect by the DIP Switch
setting to “customer mode”, otherwise
it decides by DIP Switch setting to
Test or Normal Mode.
0
Bit2
: Disable the door/window
function. (1:Disable, 0:Enable)
0
Bit3
: Setting the temperature scale.
0:
Fahrenheit
, 1:
Celsius
0
Bit4
: Disable the illumination report
after event triggered. (1:Disable,
0:Enable)
0
Bit5
: Disable the temperature report
after event triggered. (1:Disable,
0:Enable)
NO
.
Name
Def.
Vali
d
A B C
Description
0
Bit6
: Reserve.
0
Bit7:
Disable the back key release
into test mode. (1:Disable,
0:Enable)
7
(*)
Customer
Function
4
All
Customer function switch, using bit
control.
Caution
: The value is unsigned byte,
the range is from 0x00 ~ 0xFF.
0
Bit0
: Reserve.
0
Bit3
: Disable send out BASIC OFF
after door closed. (1:Disable,
0:Enable)
0
Bit4
: Notification Type,
0: Using Notification Report.
1: Using Sensor Binary Report.
0
Bit5
: Disable Multi CC in auto report.
(1:Disable, 0:Enable)
0
Bit6
: Disable to report battery state
when the device triggered. (1:Disable,
0:Enable)
0
Bit7
: Reserve.
10
Auto
Report
Battery
Time
12
0 ~
127
The interval time for auto report the
battery level.
0 means turn off auto report battery.
The default value is 12. The tick time
can setting by the configuration No.20.
11
Auto Report
12
0 ~
The interval time for auto report the
6