NO
.
Name
Def.
Vali
d
A B C
Description
Door/Windo
w State
Time
127
door/window state.
0 means turn off auto report
door/window state.
The default value is 12. The tick time
can setting by the configuration No.20.
12
Auto Report
Illumination
Time
12
0 ~
127
The interval time for auto report the
illumination.
0 means turn off auto report
illumination.
The default value is 12. The tick time
can setting by the configuration No.20.
13
Auto Report
Temperatur
e Time
12
0 ~
127
The interval time for auto report the
temperature.
0 means turn off auto report
temperature.
The default value is 12. The tick time
can setting by the configuration No.20.
20
Auto Report
Tick
Interval
30
0 ~
0xFF
The interval time for auto report each
tick. Setting this configuration will
effect configuration No.10, No.11,
No.12 and No.13.
The unit is 1 minute.
Caution1
:
Setting to
0
means turn
off all auto report function.
Caution2:
The value is unsigned
byte, the range is from 0x00 ~ 0xFF.
Z-Wave Supported Command Class
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_SENSOR_MULTILEVEL_V5
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_MULTI_CMD
COMMAND_CLASS_SECURITY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Specifications
Power by CR123A lithium battery.
Signal (Frequency):
DCH-112: 868.40 MHz, 869.85 MHz(EU),
DCH-112: 908.40 MHz, 916.00 MHz(US),(Canada)
DCH-112: 922~927 MHz(JP/TW),
DCH-112: 921.40 MHz, 919.80 MHz(ANZ),
Range:
Minimum 40 meters indoor,
100 meters outdoor line of sight.
Operating Temperature: -10
o
C ~ 40
o
C
For indoor use only.
Specifications subject to change without notice due to continuing
product improvement.