background image

* Wake

When the device power on, the device will wake about 20 seconds. In

this duration, the controller can communicate with the device. Normally

the device is always sleeping to save the battery energy.

Security Network

The device support the security function. When the device included

with a security controller, the device will auto switch to the security

mode. In the security mode, the follow commands need using Security

CC wrapped to communicate, otherwise it will not response.

COMMAND_CLASS_BATTERY

COMMAND_CLASS_NOTIFICATION_V4

COMMAND_CLASS_ASSOCIATION_V2

COMMAND_CLASS_CONFIGURATION

COMMAND_CLASS_SENSOR_BINARY_V2

COMMAND_CLASS_SENSOR_MULTILEVEL_V5

COMMAND_CLASS_WAKE_UP_V2

Operation Mode

There are two modes “Test” and “Normal”. 

“Test Mode” is for the user test the sensor function when installation.

“Normal Mode” for the normal operation.

When the event triggered, normally the LED won't indicated, unless the

battery is in the low level, the LED will flash once. But in the “Test

Mode” the LED also will light ON one second.

When the event triggered, the device will report the messages to the

nodes in the group 1. The messages also include the battery level, the

temperature and the illumination level. The user can switch the report

by   setting   the   configuration   NO.   5   bit4   (illumination)   and   bit5

(temperature), and the configuration NO. 7 bit6 (battery). 

When the event triggered, if the environment luminance is less than

the setting of the value of the configuration NO. 4, the device will emit

the signal to turn ON the lighting equipment, those nodes are in the

group 2. And delay a while to turn OFF the lighting equipment. The

delay time is setting by the configuration NO. 9. 

Notice: 

When the tamper key of the back side is released, the device

always in the “Test Mode”, no matter the DIP switch setting.

Battery Installation

When   the   device   report   the   low   battery   message.   The   user   should

replace the battery to new one. The battery type is CR123A, 3.0V.

The way to open the front cover please follow below steps. 

1. Using a tool to press the 1-1 position, to release the cover.

2. Hold the front cover and pull back

3. Hold the front cover and pull up

Replace the new battery and install the cover back.

4

Summary of Contents for DCH-112

Page 1: ...s The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve about 10 meters in indoor Support 100 Kbps transmit speed speed up communication Add to Remove from Z WaveTM Network There are two tamper keys in the device one is in the back side another is in the front side Both of them can add remove reset or association...

Page 2: ...ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM device before trying to add it to a Z WaveTM network Notice 2 When the device into NWI mode the sensor functionality will useless The NWI mode will timeout after 30 seconds You can press the tamper key 3 times to abort the NWI mode Z WaveTM Notification After the device adding to the network it will wake up once per day in ...

Page 3: ...ery 6 hours report once in default It could be changed by setting the configuration NO 10 Low battery report When the battery level is too low every 30 minutes will report once Door window state report Every 6 hours report once in default It could be changed by setting the configuration NO 11 Illumination level report Every 6 hours report once in default It could be changed by setting the configur...

Page 4: ...also will light ON one second When the event triggered the device will report the messages to the nodes in the group 1 The messages also include the battery level the temperature and the illumination level The user can switch the report by setting the configuration NO 5 bit4 illumination and bit5 temperature and the configuration NO 7 bit6 battery When the event triggered if the environment lumina...

Page 5: ...he device trig please associate with the device into the second group 3 In the accessory pack There are two type of double coated tape one is thicker hereinafter referred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let ...

Page 6: ...report after event triggered 1 Disable 0 Enable 0 Bit5 Disable the temperature report after event triggered 1 Disable 0 Enable NO Name Def Vali d A B C Description 0 Bit6 Reserve 0 Bit7 Disable the back key release into test mode 1 Disable 0 Enable 7 Customer Function 4 All Customer function switch using bit control Caution The value is unsigned byte the range is from 0x00 0xFF 0 Bit0 Reserve 0 Bi...

Page 7: ...Setting to 0 means turn off all auto report function Caution2 The value is unsigned byte the range is from 0x00 0xFF Z Wave Supported Command Class COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_BATTERY COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_SE...

Page 8: ...wever there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between t...

Page 9: ...s substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge 9 ...

Reviews: